Table 1.2:
IEMP036, 042, 048
specifications
Model name
IEMP031J3A
IEMP036J3A
IEMP042J3A
IEMP048J3A
Power supply
1-phase, 220-240V, 50Hz
Cooling
Capacity
W
9000(2700~9600)
10500(3000~11200) 12000(3000~12000)
13800(4200~13800)
Input
(IDU+ODU)
W
3060(670-3480)
3400(820-4200)
4850(820~5300)
6100(1200~6100)
Input(IDU)
W
291
291
291
291
EER
/
3.08
3.09
2.47
2.26
Heating
Capacity
W
10000(2800~10500) 11600(3100~12800) 13200(3100~13200)
16000(4500~16000)
Input(IDU+ODU)
W
2900(650-3570)
3300
(
800-4300
)
4200(800~4300)
5200(1000~5200)
Input(IDU)
W
291
291
291
291
COP
/
3.23
3.52
3.14
3.08
Fan motor
Model
YSK140-4P
Type
Ac motor
Brand
Welling
Welling/Match Well/Xin jun
Speed (H/M/L)
r/min
960/780/700
960/780/700
Coil
Number of rows
3
4
4
3
Tube pitch × row pitch
mm
21×19.4
21×13.37
Fin spacing
mm
1.5
Fin type
Arc shutter
Tube OD and type
mm
Ф7, Copper pipe with internal thread
Dimensions (L×H ×W)
mm
955×336×58.2
955×168×53.48
Number of circuits
8
Airflow rate
m3/h
1500/1200/1070
External static pressure
Pa
50(0-100)
50(0-100)
50(0-100)
50(0-100)
Sound pressure level
dB(A)
45/39/36
45/39/36
45/39/36
46/39/36
Unit
Net
dimensions
(W×H×D)
mm
1140×270×710
Packed dimensions
(W×H×D)
mm
1355×350×795
Net/Gross weight
kg
37/43(38.5/44.5)
4
39/45(40.5/46.5)
4
Refrigerant type
R410A
Design pressure (H/L)
MPa
4.4/2.6
Pipe
connections
Liquid/Gas pipe
mm
Ф9.5/Ф15.9
Ф9.5/Ф15.9
Ф9.5/Ф15.9
Ф9.5/Ф15.9
Drain pipe
mm
Ф25
Ф25
Ф25
Ф25
Piping Length
m
30
30
30
50
Level Difference
m
20
20
20
25
Controller
WDC-86E/K
Note:
1. The design implementation standard of this unit is GB/T 18836-2017.
2. The parameters in the table are the nominal values tested under the rated working conditions specified in GB/T 18836-2017, and actual
operating parameters will vary with the working conditions.
3. The above parameters may change due to product improvement. Please refer to the nameplate parameters of the product
4. Models with water pump and filter.
Summary of Contents for OTEC IEMP-D Series
Page 1: ...IEMP D Series Ducted Fan Coil Technical Manual...
Page 4: ...2 Part 1 General information 1 Model Names of Indoor Outdoor Units 3 2 External Appearance 4...
Page 17: ...17 ICHD031J0A DMG090...
Page 18: ...18 ICHD036J0A DMG105 ICHD042J0A DMG120 ICHD048J0A DMG140...
Page 19: ...19 ICHD060J0A DMG160...
Page 29: ...36 IEMP031J3A DCG090 IEMP060J3A DCG160...
Page 30: ...37 IEMP036J3A DCG105 IEMP042J3A DCG120 IEMP048J3A DCG140...
Page 86: ...126 IEMP031 36 42 48 60 J3A DCG090 105 120 140 160...