Procedure: Required For Operation
Before the vehicle will start, you must follow the DataLearn
TM
Procedure.
Orange Wire: Connection Optional
The Orange wire is an engine speed or tachometer sensing wire. The RS-4LX utilizes
two different methods of monitoring the vehicle during the remote starting process. Con-
sider both methods before deciding which one to use. Normally the Smart Tach
TM
method
is used.
Smart Tach
TM
remote starting (factory setting):
This method does not require the connection of the Orange tach wire. This method uses a
voltage sensing circuit which reads the vehicle's voltage before attempting to start, and
This process allows the RS-4LX to determine the normal operating conditions of sev-
eral key vehicle circuits. This procedure must be followed in the following steps:
1)
Press and hold the brake pedal.
2)
While holding the brake pedal, turn the ignition key to the "Run" (not "Start")
position.
3)
Move the gear shift selector from "Park" to any forward or reverse gear.
4)
Move the gear shift selector back to the "Park" position, then release the brake
pedal. Turn the ignition key "off".
To confirm the Data Learn Procedure, toggle the Override Switch OFF and ON once.
The Diagnostic LED Light on the RS-4LX will flash once.
Page - 16
Page - 25
Continued Next Page
DataLearn
TM
Procedure: Required For Operation
Before the vehicle will start, you must follow the DataLearn
TM
Procedure.
Orange Wire: Connection Optional
The Orange wire is an engine speed or tachometer sensing wire. The RS-4LX utilizes
two different methods of monitoring the vehicle during the remote starting process. Con-
sider both methods before deciding which one to use. Normally the Smart Tach
TM
method
is used.
Smart Tach
TM
remote starting (factory setting):
This method does not require the connection of the Orange tach wire. This method uses a
voltage sensing circuit which reads the vehicle's voltage before attempting to start, and
This process allows the RS-4LX to determine the normal operating conditions of sev-
eral key vehicle circuits. This procedure must be followed in the following steps:
1)
Press and hold the brake pedal.
2)
While holding the brake pedal, turn the ignition key to the "Run" (not "Start")
position.
3)
Move the gear shift selector from "Park" to any forward or reverse gear.
4)
Move the gear shift selector back to the "Park" position, then release the brake
pedal. Turn the ignition key "off".
To confirm the Data Learn Procedure, toggle the Override Switch OFF and ON once.
The Diagnostic LED Light on the RS-4LX will flash once.
Page - 16
Page - 25
Continued Next Page
Factory Setting (2 LED flashes)
Option (1 LED flash)
#1 Smart Tach
Tach wire connection required
#2 10 minute run time
15 minute run time
#3 Normal Starter
Extended starter
#4 Normal Starter
Super extended starter
#5 Voltage supervision
No voltage supervision
#6 Gasoline engine
Diesel engine
#7 Pre-activation enable
No pre-activation enable
#8 Single Pulse Activation
Double Pulse Activation (Lock-Lock-Start)
Note: The number of LED flashes referred to are used when changing the factory settings.
#1 Determines how the RS-4LX will monitor engine speed. Smart Tach uses volt-
age level monitoring, while the option monitors AC voltage from the negative side of
the coil.
#2 This option sets the run time before the unit automatically shuts off the engine.
#3 This option adds 50% more starter engagement time. This feature is useful on difficult-
to-start engines.
#4 Adds 100% more starter engagement time. This option is necessary for some diesel
applications and very difficult-to-start engines.
#5 This is used with the Smart Tach method of monitoring engine speed by measuring
voltage from the alternator's output.
#6 This option is for diesel engine remote start applications, and requires connected of the
Gray glow plug wire.
Factory Setting (2 LED flashes)
Option (1 LED flash)
#1 Smart Tach
Tach wire connection required
#2 10 minute run time
15 minute run time
#3 Normal Starter
Extended starter
#4 Normal Starter
Super extended starter
#5 Voltage supervision
No voltage supervision
#6 Gasoline engine
Diesel engine
#7 Pre-activation enable
No pre-activation enable
#8 Single Pulse Activation
Double Pulse Activation (Lock-Lock-Start)
Note: The number of LED flashes referred to are used when changing the factory settings.
#1 Determines how the RS-4LX will monitor engine speed. Smart Tach uses volt-
age level monitoring, while the option monitors AC voltage from the negative side of
the coil.
#2 This option sets the run time before the unit automatically shuts off the engine.
#3 This option adds 50% more starter engagement time. This feature is useful on difficult-
to-start engines.
#4 Adds 100% more starter engagement time. This option is necessary for some diesel
applications and very difficult-to-start engines.
#5 This is used with the Smart Tach method of monitoring engine speed by measuring
voltage from the alternator's output.
#6 This option is for diesel engine remote start applications, and requires connected of the