21
Electrical Components
In the ultrasonic bath, preheat 1 part Omega AquaClean with 64 parts clean water to
a temperature of 115
˚F. A higher dilution may be required depending on the severity
of contamination.
If it exists, excess water should be removed as quickly as possible.
UnWet CPDL should be used to stabilize the components if moisture exists, prior to
cleaning.
Vacuum excess soot with a HEPA-style vacuum prior to placing in bath.
Pre-spray the outside of the components with a 1 part OmegaSmoke, 64 parts clean
water mixture. Let sit for 2
– 5 minutes depending on the degree of the exterior soot.
Place components in basket, do not stack, and clean for 2 minutes.
Remove the basket from bath and rinse with free flowing de-ionized water.
Blow off excess water with compressed air.
Place a bowl of 1 part Omega Deodorizer and 1 part clean water at the bottom of the
drying chamber and dry the electronics for 10 hours at 120
˚F.
Ensure that the items are dry before connecting to a power source.