3

DMX512 channels: 

 

No. 

function 

Detail function 

1CH 

Total dimming 

R

G

B dimming from dark to bright 

2CH 

Total strobe 

R

G

B strobe from slow to quick 

 

3CH 

 

Function     

selection 

0 -    50 DMX 7ch control

 

51- 100 jump change

 

151-200 Gradient, variable pulse; 

201—255

sound action 

4CH 

Function speed 

From slow to quick 

5CH 

R dimming 

Linear dimming, from dark to bright 

6CH 

G dimming 

Linear dimming, from dark to bright 

7CH 

B dimming 

Linear dimming, from dark to bright 

 

Cleaning 

Due to fog residue, smoke, and dust cleaning the internal and external optical 

lenses must be carried out periodically to optimize light output. 

 
1.

 

Use a soft cloth to wipe down the outside casing.   

 
2.

 

Clean the external optics with a soft cloth every 20 days. Cleaning frequency 

depends on the environment in which the fixture operates (i.e. smoke, fog 

residue, dust, dew).   

 