background image

AccuTrac / RhinoTrac Owner’s Manual

  Page 5

AccuTrac EZ and RhinoTrac EZ tools

 are designed for the exclusive use with fasteners and plates (washers) made by OMG Roofing Products. OMG Roofing 

Products is not responsible for damage to the tool and/or improper installation caused from using fasteners and/or plates other than those recommended in this 

manual.

AccuTrac EZ

 is designed for use with 3-inch square AccuTrac Insulation Plates, and approved fasteners manufactured by OMG Roofing Products.  

RhinoTrac EZ

 is designed for use with specially coated, 3-inch round, RhinoBond Plates and approved fasteners manufactured by OMG Roofing Products.

 

  POWER REQUIREMENTS

  FASTENER COMPATIBILITY

CORD LENGTH

25-ft.

50-ft.

75-ft.

100-ft.

125-ft.

150-ft.

WIRE SIZE

18-Ga.

16-Ga.

14-Ga.

14-Ga.

12-Ga.

12-Ga.

  INTENDED USE

AccuTrac EZ and RhinoTrac EZ tools

 are intended for installing OMG Roofing Products Fasteners and Insulation Plates or RhinoBond Plates on commercial roofing 

projects. Only fasteners and plates (i.e. washers) specified and provided by OMG Roofing Products are approved for use with these tools. Do not use these tools for 

any other purpose.
AccuTrac EZ and RhinoTrac EZ tools can injure people and damage property. Please be sure that you and all crew members read and understand the instructions 

in this manual (as well as those in the Owner’s Manual for the screw-gun component) before attempting to use these tools. Failure to follow all instructions could 

result in property damage, serious injury, electric shock, or death.

PLEASE NOTE: 

This manual deals only with the use and operation of the AccuTrac EZ and RhinoTrac EZ tool. For specific information about the use, operation, and 

limitations of the screw-gun component of the tool, refer to the separate Owner’s Manual provided by the screw gun manufacturer, which has been included with 

the tool.

AccuTools are compatible with the following fasteners manufactured by OMG Roofing Products. Maximum fastener length is 8-inches. 

 

- Standard #12 RoofGrip Fasteners
- Heavy Duty #14 Roofing Fasteners
- Extra Heavy Duty (XHD) #15 Fasteners

Extension cords must be of adequate wire size for safety, to prevent loss of power and to avoid over-heating the tool. Refer to the chart below for the minimum wire 

size requirements.

NOTICE

Summary of Contents for AccuTrac EZ

Page 1: ...ES ROAD AGAWAM MA 01001 USA 800 633 3800 413 789 0252 RHINOBOND COM New EZ Indicator Technology shows users when plate and fastener are ready for installation IMPORTANT Save this manual and read it in...

Page 2: ...E NOTE This manual deals only with the use and operation of the AccuTrac EZ and RhinoTrac EZ tool For specific information about the use operation and limitations of the screw gun component of the too...

Page 3: ...tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Arcing could occur which could ignite the dust or fumes c Keep children and bystanders away while operating p...

Page 4: ...re idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untra...

Page 5: ...OMG Roofing Products are approved for use with these tools Do not use these tools for any other purpose AccuTrac EZ and RhinoTrac EZ tools can injure people and damage property Please be sure that yo...

Page 6: ...indica tors alert users to avoid loading two screws at the same time Redesigned plate shuttle links are easier to compress for all day comfort Accomplish more projects with interchangeable boots for i...

Page 7: ...uth funnel 3 Lock the screw gun trigger in the ON position Using the lock will keep the screw gun running cooler Push the tool downward to drive the screw through the insulation until it contacts the...

Page 8: ...red and black Star Knobs See page 12 par EZ1283214 at the top of the shaft on the screw gun motor mount 2 Pull screw gun straight up You might need to pull a little bit harder to get the screw gun out...

Page 9: ...es it may be necessary to release the flags in the end of the nose piece to fully access the jam The flags can be released by pinching the top of both flags together 3 For clearing plate jams first ma...

Page 10: ...e 242 and reinstall screws Plate retaining spring is not completely seated Turn the handle clockwise and gently pull upward Plate rod is not completely seated Turn the handle clockwise and gently pull...

Page 11: ...g upwards Plate Shuttler or tubes are dirty Clean and oil Plate Shuttler and tubes Nose piece is bent or damaged Call 1 413 789 0252 for service Do not attempt to remove nose piece Fastener wedged bet...

Page 12: ...AccuTrac RhinoTrac Owner s Manual Page 15 NOTES...

Page 13: ...OMG Roofing Products 153 Bowles Road Agawam MA 01001 USA 800 633 3800 413 789 0252 www rhinobond com...