GENERAL

1.  Use only with approved plates and fasteners manufactured by OMG Roofing Products. See page 5 for details.
2.  At the beginning of each day, wipe down the tubes and the bottom of the ejector plate. Lubricate the linkage and the  

  plate Plate Shuttler, if needed, then unlatch the tool.
3.  Load the plate holder with the proper plates.
4.  Make sure the screw gun is in the FORWARD mode. Connect  

  the tool to the proper power source.
5.  At the end of the day, remove any dust accumulation from the  

  tubes and the bottom of the Plate Shuttler.
6.  Lubricate all moving parts. Excess lubricant will evaporate overnight.
7.  Re-latch the tool and store it in its case. 

LOADING PLATES

1.   Remove the plate weight from the plate holder.
2.  Remove the pre-packaged plates from the box. 

For AccuTrac EZ, align  

  the notch in the plates with the projection on the back side of the  

  plate holder.

3.  Drop the plates into the holder and return the plate alignment shaft and weight to the holder.

OPERATING THE TOOL

1.  Fully compress the tool to allow a plate to be ejected from the stack and placed into proper position. 
2.  Drop one screw, point down, into the wide mouth funnel.
3.  Lock the screw gun trigger in the ON position. Using the lock will keep the screw gun running cooler.  

  Push the tool downward to drive the screw through the insulation until it contacts the deck.  

  Continue to hold down on the tool until the plate is fully seated.
4.  Allow the tool to retract to its original position. This motion causes the next plate to be ejected from  

  the stack for placement.
5.  Check the plate to make sure it is properly seated and adjust fastener depth if necessary.
6.  Roll the tool to the next fastener/plate position on the roof and repeat the “tool use” instructions.
 

DEPTH ADJUSTMENT

Overdriving can cause the screw to strip out the metal deck and not hold. The tool should be adjusted 

to make the plate snug so that it does not spin freely on the surface. The plate should not be so tight  

as to cause it to deform or to fracture the insulation.
To avoid overdriving, set the adjustment intentionally loose, and slowly tighten until you get the  

proper depth.
Adjustments are made using the large ring located on the upper body tube of the tool.  

Moving the ring upwards towards the screw gun (i.e. counter-clockwise) will  

make the screw deeper (tighter).

 

If you are unable to make the plate “snug” through adjusting the depth adjustment nut, make  

sure that the screw gun is in the forward position (not reverse).

OPERATING INSTRUCTIONS

NOTICE

Loose

Tight

Summary of Contents for AccuTrac EZ

Page 1: ...ES ROAD AGAWAM MA 01001 USA 800 633 3800 413 789 0252 RHINOBOND COM New EZ Indicator Technology shows users when plate and fastener are ready for installation IMPORTANT Save this manual and read it in...

Page 2: ...E NOTE This manual deals only with the use and operation of the AccuTrac EZ and RhinoTrac EZ tool For specific information about the use operation and limitations of the screw gun component of the too...

Page 3: ...tools in explosive atmospheres such as in the presence of flammable liquids gases or dust Arcing could occur which could ignite the dust or fumes c Keep children and bystanders away while operating p...

Page 4: ...re idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untra...

Page 5: ...OMG Roofing Products are approved for use with these tools Do not use these tools for any other purpose AccuTrac EZ and RhinoTrac EZ tools can injure people and damage property Please be sure that yo...

Page 6: ...indica tors alert users to avoid loading two screws at the same time Redesigned plate shuttle links are easier to compress for all day comfort Accomplish more projects with interchangeable boots for i...

Page 7: ...uth funnel 3 Lock the screw gun trigger in the ON position Using the lock will keep the screw gun running cooler Push the tool downward to drive the screw through the insulation until it contacts the...

Page 8: ...red and black Star Knobs See page 12 par EZ1283214 at the top of the shaft on the screw gun motor mount 2 Pull screw gun straight up You might need to pull a little bit harder to get the screw gun out...

Page 9: ...es it may be necessary to release the flags in the end of the nose piece to fully access the jam The flags can be released by pinching the top of both flags together 3 For clearing plate jams first ma...

Page 10: ...e 242 and reinstall screws Plate retaining spring is not completely seated Turn the handle clockwise and gently pull upward Plate rod is not completely seated Turn the handle clockwise and gently pull...

Page 11: ...g upwards Plate Shuttler or tubes are dirty Clean and oil Plate Shuttler and tubes Nose piece is bent or damaged Call 1 413 789 0252 for service Do not attempt to remove nose piece Fastener wedged bet...

Page 12: ...AccuTrac RhinoTrac Owner s Manual Page 15 NOTES...

Page 13: ...OMG Roofing Products 153 Bowles Road Agawam MA 01001 USA 800 633 3800 413 789 0252 www rhinobond com...