AccuTrac / RhinoTrac Owner’s Manual
Page 8
PARTS REMOVAL AND REPLACEMENT
NOTICE
Always use OMG Roofing Products replacement parts.
FEED TUBE REMOVAL AND REPLACEMENT
1. Disconnect the upper link from the feed tube assembly by sliding the metal bushings inward and pushing the upper link forward to disengage. Repeat the
process for the opposite upper link.
2. The tool can now be removed from the base by pulling up on the tool.
3. Once the tool is separated from the base, you can remove the feed tube from the upper tube by pulling on the spring-loaded retention pin and separating it from
the bracket on the upper tube. The feed tube should now release from the tool.
4. To reinstall the feed tube, align the lower end so that the “ears” engage the notches of the lower tube.
5. Angle the feed tube towards the upper tube and reinstall the retention pin into the bracket.
6. Reattach the upper links by sliding the metal bushings inward and connecting the links.
CAUTION
The nose-piece is not to be removed!
1. The nose piece is under spring-loaded pressure. Attempting to remove the nose piece could cause personal injury. See warning sticker on tool!
2. Shuttle links are pinch points. Use caution when disconnecting them to avoid injury.
3. Contact 413.789.0252 to locate the nearest authorized OMG Roofing Products AccuTrac EZ Distributor and/or service center.
1. Loosen both red and black “Star Knobs” (See page 12, par# EZ1283214) at the top of the shaft on the screw gun motor mount.
2. Pull screw gun straight up. You might need to pull a little bit harder to get the screw gun out.
3. To reattach the screw gun, simply align the screw gun with the motor mount, push screw gun collar/chuck into the mount untilyou hear a click. Make sure the
collar/chuck of the screw gun is flush with the mount.
1. Remove the screw gun and drive shaft assembly as described above. DO NOT separate the screw gun from the drive shaft.
2. Carefully inspect the drive shaft, bit cap and bit assembly for excessive wear, cracks and/or damage of any kind. If either the shaft, bit cap or bit requires replacing,
use assembly part number EZ1282028 (Universal drive shaft), EZ1283058 (Phillips cap) and SPD11 (Phillips bit).
3. When replacing a Phillips bit, align bit cap with wrench cut-out on the boot linkage, insert the bit cap all the way through the cut-out, put the screwgun in reverse,
push on the driveshaft to engage the clutch and slowly push the trigger to unscrew the bit cap. Once the bit cap is loosened, simply pull the Phillips bit out
Alternatively, two wrenches can be used to loosen the bit cap.
4. Once the Phillips bit is replaced, put the bit cap back on and hand tighten. DO NOT use the wrench cut-out to tighten the bit cap. Two wrenches can also be
used to tighten the bit cap.
5. Reinstall the drive shaft assembly into the screw gun making sure it snaps into place as described in the previous section.
SCREW GUN REMOVAL AND REPLACEMENT
DRIVE SHAFT, BIT CAP, AND BIT