MANUAL CALIBRATION
We recommend using the tool in OptiWeld mode, but recognize that you may want to adjust the weld settings from time to time, so we’ve made it easy to do that.
Here’s how:
From the “Device Ready” screen, press the “Mode” button, and select the “Manual” option.
Select the “Manual” option.
The “Energy Level” button displays the current energy setting that will be delivered to the RhinoBond plate.
To adjust the “Energy Level” setting, push the plus (+) or minus (-) buttons.
Push the “Save” button once the energy setting is set.
The screen will automatically return to the “Device Ready” screen.
The “Device Ready” screen will display the current energy setting (i.e. +5).
In addition, you’ll see that the tool is in “Manual” mode, and can see the current power/voltage display and the
day’s activations.
Press the trigger on the handle to activate the weld cycle.
Once the weld is complete, the RhinoBond tool will emit a beep, provided that the sound is turned on (see pg 11)
and display the”Activation Done” screen.
The tool will automatically return to the “Device Ready” screen for the next weld.