Generators should be 5,000 watt (minimum) in good working order. “Auto throttle” and/or “auto idle”
switches MUST be in OFF position.
RhinoBond tools are designed to run on 100–240V. Use a true RMS multimeter to verify voltage at both
the generator, and at end of extension cord.
12 gauge (minimum), 100-feet (maximum) extension cord
per RhinoBond Tool. Inspect power cords
regularly for signs of damage; replace as necessary.
Safely operate a maximum of two RhinoBond tools per 5,000 watt generator, with each tool plugged into
a
separate 20A, GFCI circuit.
Dedicated power source: No other equipment should be plugged into RhinoBond generator during operation!
DO NOT
plug the tools into a pigtail.
DO NOT
plug RhinoBond tools into a 15A GFCI adaptor.
POWER REQUIREMENTS CHART
REGION
USA / CANADA
UK / IRELAND
NETHERLANDS
AND REST OF EUROPE
CHINA
POWER REQUIREMENTS
120V / 20A / 50-60 Hz
110-230V / 16 A / 50-60 Hz
220-230V / 10 A / 50-60 Hz
220V, 50Hz
EXTENSION CORD
12 gauge (min.), 100-ft. (max.)
110V, 2.5mm X 30m
16A (230V 3x15), 30m
10A, 30m
PORTABLE GENERATOR
POWER SOURCE
5,000W min. with (2)
20A GFCI Circuits
2.5 KVA min. with 16Amp (110V)
protected circuit
2.5 KVA min. with 10Amp (230V)
protected circuit
Honda EU20i 1.6 KVA w/ 8 Amp
(230V) protected circuit
# RhinoBond tools per
GENERATOR *
2
1
1
1
INTENDED USE
The RhinoBond System
is intended for installing thermoplastic (i.e. TPO and PVC) and “Clean EPDM” roofing membranes on commercial, industrial, institutional
and appropriate residential roofs. Its sole purpose is to bond, by induction means, the bottom side of the roofing membrane to a washer or plate installed to hold
insulation and other roofing components in place and serve as an attachment point for the induction welding process. Only fasteners, washers and tubes provided
by OMG Roofing Products are approved for use with the RhinoBond System. Do not use this tool for any other purpose.
The RhinoBond Tool is designed to operate on universal power, from 100 to 240 Volt sources. See the power requirements chart below for your region.