Failure to follow safe installation guidelines could result in death or
serious injuries.

Make sure the

Datalog X-PRO

is installed by qualified personnel

and in accordance with the applicable practice code.

Use the device only as specified in this manual. Failure to do so may
impair the protection provided by it.

Inappropriate or incorrect use of the product may result in hazards
and application-specific malfunctioning; such as damage to system
components, due to incorrect mounting or adjustments.

Do not perform any services besides those covered in this manual,
unless you are qualified.

Any substitution of non-authorized parts or repair, other than
exchanging the sensors is prohibited.

Unauthorized changes to the product are strictly prohibited as they
may unintentionally and unpredictably alter the performance and
safety.

Unauthorized changes that interfere with the integrity of the
enclosure or mounting holes, such as making additional
perforations, compromise the product integrity and safety.

Equipment ratings and certifications are no longer valid on any
products that have been damaged or modified without the prior
written permission of Omicron IoT Solutions

. Any continued use of

a product that has been damaged or modified without prior written
authorization is at the customer's sole risk and expense.

Explosions could result in death or serious injuries.

Verify that the operating environment of the device is consistent
with its environmental specifications.

This device is not intended for use in flammable or combustible
atmospheres.

omicroniot.com

6

June

2023

Summary of Contents for DATALOG X-PRO 2.0

Page 1: ...DATALOG X PRO 2 0 IoT MULTISENSOR WIRELESS DEVICE for LoRaWAN Sigfox and GSM networks Quick Start Guide omicroniot com 1 June 2023...

Page 2: ...e record of changes per manual version Version Date Description 1 1 14 03 2023 Format change Extensive revision and correction of content Technical background information update 1 2 24 06 2023 Version...

Page 3: ...8281 Monday through Friday 7 00 a m to 5 00 p m Eastern Standard Time You can also write to solutions omicroniot com specialized personnel will discuss your application case Please have the following...

Page 4: ...ymbol The notices shown below are graded according to the previous definitions Refer to the safety messages indicated by this standard at the beginning of each section before interacting with the devi...

Page 5: ...O 9 2 2 1 Indoor use AC DC adapter connection Supplied 9 2 2 2 Outdoor use Connection to a solar panel or to an industrial power supply Not Supplied 10 2 3 Turn on the device 12 2 4 Send data via Sigf...

Page 6: ...Unauthorized changes to the product are strictly prohibited as they may unintentionally and unpredictably alter the performance and safety Unauthorized changes that interfere with the integrity of the...

Page 7: ...y and carefully before installing and setting up the product The procedures and instructions in this manual may require special precautions to ensure the safety of the personnel performing the operati...

Page 8: ...refer to Section 5 1 of the User s Manual of the Datalog X PRO NOTE A sensor can be installed in any of the three Datalog X PRO ports however once the installation is complete it is necessary to rela...

Page 9: ...supply from 12 to 24 VDC or a Solar Panel with the proper terminal Likewise and only for indoor use the user can connect the device to a 12 VDC AC DC power adapter supplied Exceeding the voltage rang...

Page 10: ...r system the output rating must be limited to 12VDC 0 5A or 24VDC 0 25A for a single Datalog X PRO In any case a 12VDC 0 5A 6W or 24VDC 0 25A 6W fuse and circuit breakers should be used between the po...

Page 11: ...Calculate the value of the fuse and the primary breaker to protect the system depending on the energy generated by the solar panel and the recommendations given by the manufacturers of the solar pane...

Page 12: ...state The equipment also turns off when it is disconnected from its power sources or is forced to do so after approaching a magnet for 10 seconds to the opposite side of the antenna To wake it up for...

Page 13: ...Figure 2 5 The LED will indicate that the magnet has been correctly approached by illuminating red After briefly approaching the magnet 2 times the main LED of the device will flash blue to show that...

Page 14: ...near the center of said clear space to leave enough margins to comfortably install its peripherals as shown below Figure 2 6 Recommended free space around the Datalog X PRO To secure the Main Unit en...

Page 15: ...e with the delivery to the Main Unit using the screws provided by the manufacturer 3 Finally fasten the Main Unit to its pole using proper mounting straps Figure 2 8 Reference example of a similar dev...

Page 16: ...ck the dashboard of the device in the Remote Monitoring Platform After accessing the remote monitoring platform supported by the manufacturer of the Datalog X PRO you can review the information sent b...

Page 17: ...Figure 2 10 Steps to view a specific Dashboard omicroniot com 17 June 2023...

Page 18: ...ers America Regional Office Omicron IoT Solutions Address Carrera 46 38 62 Off 502 Medell n Colombia Phone 57 604 2328381 WhatsApp 57 317 4365062 comercial omicroning co www omicroniot com omicroniot...

Page 19: ...2023 Omicron IoT Solutions All rights reserved omicroniot com 19 June 2023...

Reviews: