Version February 2020
12
EN
HST 300 Smart User’s Manual
O . M . I . S . A . S r l
Via Verga 9/11
20845 Sovico (MB), Italy
processes and printing it as a label tag to be affixed to the
joint on the optionally available tag printer. The ViewWeld
abstract shows the report number, the date and time of
the welding and the welding parameters along with an
evaluation of the quality of the joint/welding operation
(see Display 6; only two lines appear on the screen, to see
those not shown, press the
ñ
and
ò
keys), where the first
displayed abstract is that of the last performed welding
operation.
To call the ViewWeld abstract of a welding report, press the
ñ
key in the bar code input screen (see Display 2). Browsing
through the saved welding reports is then possible by press-
ing the
ï
or
ð
cursor keys. To print a tag of the welding
operation of which the abstract is currently displayed, the
label tag printer has to be connected to the welder. Then
press the START/SET key in the ViewWeld screen.
6
Additional Information in the Welding Report
Every welding report saved to system memory, which can
be downloaded as a PDF report file or in the DataWork
format, contains a number of welding and traceability data
that the operator can decide to enter or not to enter in
the set-up menu.
6.1 Entering Preformatted and User-defined
Traceability Data
All traceability data enabled in the configuration menu at
“Data Recording” (see Sect. 10) have to be entered before
the welding process. The welding unit prompts the user to
enter them either before or after entering the fitting bar
code (see Display 2). Depending on what data is entered,
either its repeated input is mandatory (e. g., the welder
ID code; see Sect. 5.2) or previously entered data can be
changed and confirmed or confirmed without changes
(e. g. the commission number; see Sect. 6.2).
Certain traceability data can also be accessed quickly, via
a selection screen, by pressing the
ï
cursor key (see Dis-
play 7), either for viewing or for entering or changing/
confirming them.
6.2 Entering or Changing the Job Number
The commission number input screen is shown by the unit
before welding or accessed by the user in the quick access
screen (Display 7). It can be entered using the
ï
,
ð
,
ñ
,
ò
cursor keys or by reading it from a bar code using the scan-
Display 6
0015 24.02.13 09:33
M/B MON HST 450
0058s 025.0V 1.57Ω
Welding OK
Display 7
>Welder ID Code
Enter Job No.
Display 8
Enter Job No.
********************