background image

 

11 

 

DMAN-xxxx-xx

 

www.omnexcontrols.com

 

call toll free: 1-800-663-8806 

Light Legend  

Solid 

Slow  
Flash 

Fast  
Flash 

Red  
Light 

Green  
Light 

Alternating Red 
& Green Light 

Yellow 
Light 

Normal Operation 

Indicator 

Lights 

Description 

Solution 

Indicator 

Lights 

Description 

Solution 

 

Transmitter is OFF 

The SW 1 button is 
stuck for more than 10 
seconds  

(If the transmitter is on,  
the LINK light will be OFF)

 

Wiggle the button to try and 
get unstuck.  If condition 
persists,  contact customer 
service. 

 

During normal opera-
tion, this may indicate              
irrecoverable CAN     
software error or upon 
power-up, out of the 
box, the unit has no 
setup information or 
setup information is 
corrupt 

Proceed through the 
Download ID procedure.    
If this doesn’t work contact 
Customer Service 

 

Transmitter is OFF 

The SW 2 button is 
stuck for more than 10 
seconds  

(If the transmitter is on,  
the LINK light will be OFF) 

Wiggle the button to try and 
get unstuck.  If condition 
persists,  contact customer 
service. 

 

Setup download 
failed. 

Try again, no more than a 
couple of times, or contact 
customer service. 

 

Transmitter is OFF 

A low battery condition 
has been detected. 

To detect intermittent 
conditions caused by 
poor or corroded ground 
or power circuits, the 
GREEN light will continue 
to flash for  

 

Transmitter is OFF    

E-Stop relay failure  

(If the transmitter is ON,  
the LINK light will be fast 
flashing GREEN) 

Contact Customer Service 

Trouble Indicators 

Note: In some cases, the indicator lights will be different depending on whether the transmitter is on or off.  For all cases listed below, the transmitter’s 
status is OFF unless otherwise indicated.  Please note the transmitter status in the “Description” column for each case. 

 

Diagnostics - R170 Receiver 

Indicator 

Lights 

 

Transmitter is OFF 

If the transmitter is off, the receiver is operating properly.  This will be the status of the receiver after the Download 
ID procedure as the transmitter automatically shuts off after ID download.  

 

Transmitter is ON 

When the transmitter is turned on, the Link light (fast flashing) and E-Stop (GREEN) indicates the receiver is      
operating properly  

Description 

 

STATUS 

LINK 

ESTOP 

CAN 1 

CAN 2 

 

 

 

STATUS 

LINK 

ESTOP 

CAN 1 

CAN 2 

 

STATUS 

LINK 

ESTOP 

CAN 1 

CAN 2 

 

 

 

STATUS 

LINK 

ESTOP 

CAN 1 

CAN 2 

 

 

 

 

STATUS 

LINK 

ESTOP 

CAN 1 

CAN 2 

 

 

STATUS 

LINK 

ESTOP 

CAN 1 

CAN 2 

 

STATUS 

LINK 

ESTOP 

CAN 1 

CAN 2 

 

STATUS 

LINK 

ESTOP 

CAN 1 

CAN 2 

 

 

Summary of Contents for T150

Page 1: ...1 800 663 8806 GENERIC 6SW User Installation Configuration Manual T150 Transmitter R170 Receiver 74 1833 Coast Meridian Road Port Coquitlam BC Canada V3C 6G5 Ph 604 944 9247 Fax 604 944 9267 Toll Free...

Page 2: ...ilure and serious personal injury Installation PROVIDE A SAFETY CUTOFF SWITCH If maintenance is required the radio must be disconnected from power USE PROPER WIRING Loose or frayed wires can cause sys...

Page 3: ...or 24VDC system The R170 is a radio receiver that takes commands from an OMNEX wireless transmitter and translates the commands into SAE J1939 or other CAN bus protocols The R170 has two CAN ports and...

Page 4: ...n nectors are provided below R170 Pin Assignments Connector A Grey Pin Function 1 n c 2 n c 3 Main Ground Connection 4 Power in to E Stop Relay internally fused to 7 5A 5 Output of E Stop Relay 6 Posi...

Page 5: ...ach end device Filtering and Noise Suppression Whenever a solenoid or electromagnetic switch is controlled by the receiver it is a good practice to install a Diode across its terminals to ensure that...

Page 6: ...her the transmitter or the receiver NOTE If the transmitter is connected to the receiver with a Tether Cable completing only steps 3 and 5 is necessary it is not necessary to open the R170 case and pr...

Page 7: ...error downloading the transmitter ID If this happens try downloading the transmitter ID again as described above Pressing SW 1 again will stop the Status and Link lights from flashing RED NOTE A tran...

Page 8: ...8 DMAN xxxx xx www omnexcontrols com call toll free 1 800 663 8806 Special Features...

Page 9: ...can only operate in one of the two modes at any given time and the existing link must be terminated before another link is established While operating in Wired mode the radio modules are turned off T...

Page 10: ...light will remain on momentarily whenever a function changes On Power Up Release the E Stop button within 10 seconds to power up the transmitter or the unit will power down Normal Operation The transm...

Page 11: ...s OFF A low battery condition has been detected To detect intermittent conditions caused by poor or corroded ground or power circuits the GREEN light will continue to flash for Transmitter is OFF E St...

Page 12: ...ashing GREEN CAN1 light is OFF Set up Download ID has failed Note This should only occur when the transmitter is on and the Download ID procedure has been tried Retry the Download ID procedure and if...

Page 13: ...ut 3 seconds then goes to fast flash Battery light OFF E Stop light OFF Go to Chart 3 Activate a function Does the Active light go to solid YELLOW YES Either the switch trigger is defective or the swi...

Page 14: ...ransmitter to check if the units function correctly If not proceed to Chart 1 NO YES The transmitter code may need to be re downloaded to the receiver NO Caution Note Before you proceed with the Downl...

Page 15: ...from the transmitter Possible Solutions 1 Try the Downloading steps again 2 If this doesn t correct the problem send both the transmitter and receiver in for service Note you could try to determine wh...

Page 16: ...ered before or after replacement or repair and whether or not such damage is caused by the negligence of OMNEX Control Systems ULC OMNEX Control Systems ULC 74 1833 Coast Meridian Road Port Coquitlam...