7
B. CLEARANCES TO WALLS
CAUTION
THE DISTANCE TO A COMBUSTIBLE WALL MUST BE MAINTAINED AT 26” FROM THE HOOD. PROPERTY
DAMAGE OR DEATH CAN OCCUR IF THIS DISTANCE IS NOT MAINTAINED. DRYWALL PRODUCTS LINED WITH
PAPER SUCH AS SHEETROCK ARE COMBUSTIBLE. CLEARANCES AS INDICATED FURTHER APPLY.
combustible wall
mur combustible
combustible wall
mur combustible
41’’
1040 mm
combustible wall
mur combustible
26’’
660 mm
Manufacturer specifications:
• When placed close to a non-combustible wall leave a minimum of 4” for proper ventilation. To avoid premature aging of
your painted walls, only use mineral paint. With other paints, above clearances apply.
• Fire clearance to glass (from hearth): 31-
1/2
”.
• Fire clearance to vinyl windows: refer to window technical specifications.
IMPORTANT
Use of provided heat shield under the stationary plate is compulsory. A minimum clearance of 16” from the floor
to the top of the stationay plate strictly must apply.
Specifications