OMNI 4000/7000 Operations and Maintenance Guide
– Rev F
7-17
Maintenance
Reset Prove
The Reset Prove tab gives the Operator the ability to delete historical Meter Factor data for all or
some of the Meter Runs. The following information is reset:
•
Meter Factor History (last 10 implementations) of most recently proved Meter:
−
Date (4945
– 4954)
−
Meter Factor and Deviation: (8589 and 8590
– 8607 and 8608)
•
Last Meter Factor implementation information:
−
Temperature
– 7945
−
Pressure
– 7946
−
Density
– 7948
−
Flow Rate
– 7966
−
Density at Ref Temp/RD60
– 7944
•
Meter Factor in use at last Meter Factor implementation
– 8728
•
Net or Mass (if Meter is mass pulses) Totalizer at last Meter Factor implementation
– 5924
•
IV Totalizer at last Meter Factor implementation
– 5925
Click any individual Meter Run button (#1 through 6) to reset only that Meter Run’s prove data or
click “All Meters” to reset them all at the same time (Figure 7-7).
Figure 7-7: Reset Prove Tab