SECTION 2 — MOTOR MAINTENANCE    

2.5 PLUG REQUIREMENTS

This instrument is equipped with an electric cord and housing which is 
double insulated. The unit must be plugged into a polarized outlet that 
is properly installed and grounded in accordance with all local codes 
and ordinances.

WARNING:

 

DO NOT 

modify the plug or cord that is provided. If the plug will 

not fit the outlet, have the proper outlet installed by a qualified electrician.

WARNING:

 Reduce the risk of unintentional starting; make sure the 

speed switch is in the OFF position before plugging in the motor.

WARNING:

 

Improper connection of the equipment can result in a risk 

of electric shock.

WARNING:

 

Damaged or worn power cords should be repaired or 

replaced immediately by a qualified electrician.

2.6 WIRING DIAGRAMS

Summary of Contents for GLH

Page 1: ...REV D H258 GLH OMNI GLH GENERAL LABORATORY HOMOGENIZER USER MANUAL...

Page 2: ...defective in materials or workmanship This warranty does not include normal wear from use it does not apply to any instrument or parts which have been altered by anyone other than an employee of Omni...

Page 3: ...about your Omni GLH contact your authorized dealer or call Omni International at 800 776 4431 or 770 421 0058 DO NOT allow the machine to be submerged in any liquid DO NOT use in any setting other tha...

Page 4: ...Section 2 Motor Unit Maintenance 2 1 Motor Drive Unit 8 2 2 Brush Maintenance 8 2 3 Motor Bearings 8 2 4 Storage 8 2 5 Plug Requirements 9 2 6 Wiring Diagrams 9 2 7 Explosion Drawing 10 2 8 Replacemen...

Page 5: ...220 V 50 Hz Standards Approval Compliance 220V CE Certified 1 2 PARTS AND ACCESSORIES Prior to operation please remove all parts from the shipping container and inspect for damaged or missing parts I...

Page 6: ...operation such as for fume hood or cold room applications the optional external speed control is recommended To operate the Omni GLH with the external speed control 1 Make certain that both the extern...

Page 7: ...refer to the figure and follow these steps 1 Secure the 24 post by twisting it into the base plate and locking jam nut at the base of the post 2 Loosen the locking knob and slide the post clamp assemb...

Page 8: ...t stops working all together It probably requires a new set of brushes The average brush life for the Omni GLH is 150 hours For service or brush replacement please contact Omni International at 1 800...

Page 9: ...NG DONOTmodify the plug or cord that is provided If the plug will not fit the outlet have the proper outlet installed by a qualified electrician WARNING Reduce the risk of unintentional starting make...

Page 10: ...10 SECTION 2 MOTOR MAINTENANCE 2 7 EXPLOSION DRAWING...

Page 11: ...ld Assembly GLH11530 GLH2210 16 Motor Housing GLH115218 GLH115218 17 Filter Assembly 230V only N A GLH2201 18 Base Brush Holder GLH115213 GLH115213 19 Armature Brush GLH115217 GLH2211 20 Spring for Br...

Page 12: ...o the motor housing but does not spin This is the stator portion of the rotor stator generator probe As the rotor knife spins within the tube and collar assembly it creates a pumping action pulling th...

Page 13: ...immersion and this processing depth can be optimized by observing flow patterns and related processing results While pro cessing liquid can circulate through the two holes at the bottom of the genera...

Page 14: ...vey equipment Obtain a Decontamination Certificate from Omni International Complete the certificate and attach to the instrument or parts being returned If no Decontamination Certificate is attached a...

Page 15: ...worn and are correctly installed Replace if necessary see Section 2 2 Motor unit operating speed declines stalls intermittently or stops completely Check that the brushes are not worn and are correctl...

Page 16: ...www omni inc com OMNI GLH GENERAL LAB HOMOGENIZER Omni International Inc 935C Cobb Place Blvd Kennesaw GA 30144 800 776 4431 770 421 0058...