UPH230/10 

Bedienungsanleitung  

Manual 

UP-Multi-Thermostataktor 

Flush mounted multi 

1-Kanal 

thermostat actuator, 1-channel 

 

Bezeichnung 

Typ / Type 

Art.-No./Item N° 

Designation 

UP-Multi-Thermostataktor 1-Kanal mit Nebenstelleneingang, 
1 Schliesskontakt 8 A potentialfrei, Versorgungsspannung 230 V~ 

UPH230/10

 

3410 000

 

Flush mounted multi thermostat actuator 1-channel with extension  
input, 1 closing contact 8 A potential free, supply voltage 230 V~

 

KURZ AN LE I TUNG  

  Thermostataktor gemäss Schema anschliessen 

  Drehschalter HEX auf 0 stellen 

  LRN 2 Sekunden drücken 

  LRN-Taste des Raumfühlers in der Nähe des 

Thermostataktors betätigen. CLR leuchtet während 
einer Sekunde, danach ist der Sender eingelernt 

  Zum Beenden CLR drücken 

 

FUNK TI ONE N  

  Temperaturregelung in Einzelräumen durch 2-Punkt-

Regler mit einstellbarer Hysterese 

  Geeignet für Omnio Raumfühler RTF 

  Sollwertvorgabe auch über EEP möglich 

  Vordefinierte Betriebsarten, z.B. Nachtabsenkung 

  Automatische Frostschutzfunktion bei 8 °C 

  Umschaltung auf zweiten Sollwert mit Omnio Wand-

sender, Key-Card Schalter oder Nebenstelleneingang 

  Fenster- und Schiebetürüberwachung 

  Repeaterfunktion 

  EnOcean Equipment Profile (EEP) D2-34-00 

 

ARCO fähig (AWAG Remote Commissioning) 
 

BRI E F  I NS TR UC TI ON    

  Attach thermostat actuator according to schematic 

  Turn the rotary switch HEX to 0 

  Press LRN 2 seconds 

  Press LRN-button of indoor sensor while keeping it 

close to the actuator. CLR lights up for a second, after 
that the transmitter is programmed  

  To finish press CLR 

 

FUNC TI ONS  

  Temperature control in individual rooms by 2-point 

controller with adjustable hysteresis 

  Suitable for Omnio RTF room sensors 

  Setpoint via EEP possible 

  Predefined modes, e.g. night mode 

  Automatic frost protection at 8 °C 

  Setpoint switchover with Omnio transmitter, key-card 

switch or extension input 

  Window and sliding door surveillance 

  Repeater function  

  EnOcean Equipment Profile (EEP) D2-34-00 

 

ARCO ready (AWAG Remote Commissioning) 
 

AL LGE M E I N  

Die Omnio Aktoren (Empfänger) werden über Funksignale der Omnio Sender  an-
gesteuert. Jeder Sender kann eine unbegrenzte Anzahl von Aktoren ansteuern. Die 
Funksender werden manuell durch ein einfaches Verfahren auf den Aktor ein- und 
ausgelernt. Jedem Sender können am Aktor eine Funktion und verschiedenste Pa-
rameter zugeordnet werden. 
 
Mit ARCO-Technologie lassen sich alle Omnio Aktoren vollständig und ohne ma-
nuellen Zugriff zum Gerät per Funk konfigurieren. Die leistungsstarke Software E-
Tool  bildet  dabei  das  Herzstück,  um  Projekte  beliebiger  Grösse  bequem  am 
Schreibtisch zu planen, konfigurieren und dokumentieren. 
 

P RODUK TBE S CHRE I B UNG  

Der  Omnio  UP-Multi-Thermostataktor  UPH230/10  ist  ein  Gerät  zum  Regeln  von 
Stellventilen in Bodenheizungen oder  ähnlichen  elektrischen Verbrauchern  durch 
eine  2-Punkt-Regelung  mit  Hysterese.  Sein  potentialfreier  Ausgang  kann  von  ei-
nem Omnio Raumfühler RTF und bis zu 8 Omnio Fensterkontakten oder -griffen in 
UND-Verknüpfung  angesteuert  werden.  Der  Raumfühler  sendet  Temperatur  und 
Sollwert per Funk an den Thermostataktor. Die gewünschte Raumtemperatur lässt 
sich am Raumfühler über die Bedientasten einstellen, sie kann aber auch von ei-
nem  übergeordneten  System  vorgegeben  werden.  Über  Omnio  Funksender  sind 
verschiedene  Betriebsmodi  wie  z.B.  eine  Nachtabsenkung  anwählbar.  Fällt  die 
Temperatur unter 8 °C oder ist der Raumfühler defekt, wird automatisch die Frost-
schutzfunktion aktiviert. Mit einem konventionellen Taster am Nebenstelleneingang 
kann  auf  den  zweiten  Sollwert  umgeschaltet  werden.  Bidirektionale  Kommunika-
tion, EEP D2-34-00, ARCO fähig (AWAG Remote Commissioning). Zusätzlich kann 
bei  Reichweitenproblemen  die  eingebaute  Repeaterfunktion  aktiviert  werden. 
Geeignet für die Unter- oder Aufputzmontage in Kunststoffdosen. 
 

GE NE R AL  

The  Omnio  actuators  (receivers)  are  controlled  by  radio  signals  coming  from  the 
Omnio transmitters. Each transmitter is able to control an unlimited number of ac-
tuators. The radio transmitter can be manually programmed and deprogrammed to 
an actuator following a simple procedure. Via actuator each transmitter can be given 
a certain function and different parameters.  
 
With ARCO technology, all Omnio actuators can be configured completely by radio 
without manual access to the device. The powerful software E-Tool constitutes the 
key component for convenient  planning, configuring  and documenting projects of 
any size right at your desk. 
 

P RODUC T  D E S CRI P TI O N   

The Omnio flush mounted multi thermostat actuator UPH230/10 is a device to reg-
ulate  control  valves  in  floor  heatings  or  similar  electric  loads  through  a  two-point 
controller  with  hysteresis.  Its  potential  free  output  is  able  to  be  controlled  by  an 
Omnio  room sensor RTF and up to eight  Omnio  window contacts  or 

–handles in 

AND-operation. The  room sensor transmits temperature  and setpoint to the  ther-
mostat  actuator by  radio. The desired  room  temperature can be set  on  the room 
sensor using the control buttons, but it can also be specified by a higher-level sys-
tem.  Various  operating  modes  such  as  night  setback  can  be  selected  via  Omnio 
radio transmitters. If the temperature falls below 8 °C or if the room sensor is defec-
tive,  the  frost  protection  function  is  automatically  activated.  A  conventional  push-
button  at  the  extension  input  can  be  used  to  switch  over  to  the  second  setpoint. 
Bidirectional communication, EEP D2-34-00. ARCO ready (AWAG Remote Com-
missioning). In addition, this actuator can be used as repeater in case of range is-
sues. Suitable for flush mounted sockets. 
 

AN ZE I GE -  UN D  BE DI E NE LE M E NTE  

 
Klemmen 

  L 

Netzspannung L 110 - 240 V~ 

  N 

Netzspannung N 110 - 240 V~ 

  T 

Nebenstelleneingang 

  1 

Relaiskontakt (COM) 

  2 

Relaiskontakt (NO) 

  S 

Stellventil 

 

 
Bedienelemente 

  CLR 

Taste und LED Clear 

  LRN 

Taste und LED Learn 

  HEX 

Drehschalter 0..15 

DI S P L AY  AN D  OP E R ATI N G  E LEM E NTS  

 
Terminals  

  L 

line voltage L 110 - 240 V~ 

  N 

line voltage N 110 - 240V~ 

  T 

extension input 

  1 

relay contact (COM) 

  2 

relay contact (NO) 

  S 

control valve 

 

 
Operating eleme

nts 

  CLR 

button and LED clear 

  LRN 

button and LED learn 

  HEX 

rotary switch 0..15 

 

 

 

 

EnOcean-Technologie (868 MHz) 

Summary of Contents for UPH230/10

Page 1: ...nem Omnio Raumf hler RTF und bis zu 8 Omnio Fensterkontakten oder griffen in UND Verkn pfung angesteuert werden Der Raumf hler sendet Temperatur und Sollwert per Funk an den Thermostataktor Die gew n...

Page 2: ...belle 4 GER TEPARAMETER zu finden 1 Ger teparameter w hlen 2 Drehschalter gem ss Tabelle 4 Spalte 1 einstellen 3 Einlernmodus durch einen langen Tastendruck 2 s auf aktivieren LRN leuchtet und CLR bli...

Page 3: ...diesem Fall auch ein Temperaturf hler ohne Sollwert wel cher anstelle der Grundfunktion H01 als Funktion H09 Temperatur von Raumf hler eingelernt wird EXTERNER SOLLWERT Der Sollwert kann auch durch ei...

Page 4: ...open the heating is switched off and the frost protection function is activated at temperatures below 8 C Programmed window contacts and door handles are AND linked Defective contacts block this func...

Page 5: ...NSMITTERS Alle Sender l schen 0 2 s dr cken press 2 s 15 LRN Taste 2 s dr cken press LRN button 2 s Delete all transmitters WERKSEINSTELLUNGEN FACTORY SETTINGS Auf Werkseinstellungen zur cksetzen Acht...

Page 6: ...1 Stunde 1 1 hour 2 Stunden 2 2 hours 3 Stunden 3 3 hours 4 Stunden 4 4 hours 5 Stunden 5 5 hours 6 Stunden 6 6 hours 7 Stunden 7 7 hours 8 Stunden 8 8 hours 9 Stunden 9 9 hours 10 Stunden 10 10 hours...

Page 7: ...Aus 15 2 s dr cken press 2 s 0 dr cken press Off Level 1 Verst rkt nur Originaltelegramme 1 Level 1 Amplifies original radio telegrams Level 2 Verst rkt Originaltelegramme und bereits einmal verst rk...

Page 8: ...ted current Inductive load cos 0 6 Incandescent lamp Fluorescent lamp cos 0 9 C 140 F Schraubklemmen 4 mm Screw terminals Schutzart IP20 Protection class berspannungsschutz Overvoltage protection Daue...

Reviews: