background image

4

 

|  OMNIA VOCO® 8  - QUICK START SETUP GUIDE

Ethernet Connections

There are two 10/100 Ethernet ports on the rear panel; one interface is for control, the second is for 
L/AES67 AoIP. Connect these ports to your network switches as appropriate. If you do not 
connect the VOCO 8 to an existing network, you will need a cable connected from the control port 
directly to a Windows PC for initial configuration of the unit (see the “Remote Gateway Software” 
section of this Quick Start Guide for further details).

AC Power Connections

The VOCO 8 features redundant power supplies. This is to accommodate facilities with dual power 
feeds to each equipment rack fed from completely independent sources. Both inputs should be 
connected, preferably to completely separate AC power sources such as conditioned utility power 
and UPS/generator, or at the very least two different circuits in a rack. While the unit will still function 
with only one power supply connected, an error message will be displayed on the LCD and in the 
remote software.

Front Panel

Power LED

A (very stylish) blue LED in the lower left hand corner of the front panel indicates that AC power has 
been applied to one or both power supplies. There is no power switch. If this LED does not illuminate 
after you’ve plugged in the power cords (on both ends), ensure that the AC outlets are actually 
functional. If the outlets are providing power, try a different set of power cords. Power cords don’t 
generally fail, but stranger things have happened. If you’ve verified that it’s plugged in, tried multiple 
power cords, and the outlets are providing power but the unit still won’t power up, contact The Telos 
Alliance for further instructions. We don’t see very many dead units or outright power supply failures 
(let alone two in a single unit) but perhaps it was something you said while putting the unit in the 
rack. Try to be nicer next time.

Summary of Contents for voco 8

Page 1: ...ed mic processing for your entire facility ATTENTION This quick start guide is intended to aid with basic deployment of the VOCO 8 For further support and or questions please contact support telosalli...

Page 2: ...y UPS with power line filtering to prevent damage in case of electrical storms or power surges Your Product Warranty found in the User Manual does not cover lightning damage Information about lightnin...

Page 3: ...eceipt by end user and notice of a warranty claim must be received by Telos within the above stated warranty period and warranty coverage must be authorized by Telos Contact may be made via email supp...

Page 4: ...ation The VOCO 8 uses 2 RU of rack space and is approximately 14 deep It should mount just fine in most standard 19 equipment racks but you will want to choose a location where you can access the fron...

Page 5: ...pad These settings are controlled through the Remote Gateway software see Chapter 13 CAUTION Ensure Phantom power is only enabled on channels where it is necessary Damage may result to microphones or...

Page 6: ...n another device it MUST use the Tascam pinout not Yamaha and the cable MUST reverse the appropriate input and output pairs input to output output to input Pre manufactured cables are available which...

Page 7: ...least two different circuits in a rack While the unit will still function with only one power supply connected an error message will be displayed on the LCD and in the remote software Front Panel Powe...

Page 8: ...ghtforward once you start exploring the front panel interface n n Slightly press the control up down left or right to move around the interface The highlighted item will have a white frame surrounding...

Page 9: ...be used with a USB keyboard for entering preset titles or configuration information It s also a handy place to charge your phone or attach a USB powered light Software Updates Occasionally we may rele...

Page 10: ...k if a DHCP server is available If you wish to assign a static IP address recommended select DHCP then select Off Change the hostname IP address subnet mask gateway address DNS servers and broadcast a...

Page 11: ...lling to the Display Only section of the menu to verify the settings All other AoIP settings are performed within the Remote Gateway software Remote Gateway Software In order to configure the vast maj...

Page 12: ...network as the VOCO 8 and click Run Scan You can also add an IP address block not listed by clicking Add Custom The default port for Remote Gateway communications with the VOCO 8 is 3001 and should on...

Page 13: ...dress in the Num IP field Finally enter the user name and password for the account this connection should use Create one connection entry for each of the three default user names described below User...

Page 14: ...count essentially gives a Remote Gateway user access to the same functionality as the front panel minus the IP configuration options This account is ideal for granting operators access to basic functi...

Page 15: ...an t seem to find any controls besides preset selection and IP configuration Where is everything Most of the configuration is done through the Remote Gateway software and not from the front panel You...

Page 16: ...Right and so on If your mixer or router will not split AES EBU pairs or you want to use one microphone per AES EBU output you will need to use only the even or odd inputs Can I mount the VOCO 8 in a...

Page 17: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 18: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 19: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 20: ...1241 Superior Ave Cleveland Ohio 44114 USA 1 216 241 7225 TelosAlliance com Omnia Audio 1241 Superior Ave Cleveland Ohio 44114 USA 1 216 241 7225 TelosAlliance com 2016 TLS Corp All Rights Reserved W...

Reviews: