5-YEAR WARRANTY

In order to invoke this Warranty, the Product must be registered via Telos’ website (found at: 

http://telosalliance.com/legal/warranty

) at time of receipt by end-user and notice of a warran-

ty claim must be received by Telos within the above stated warranty period and warranty cov-
erage must be authorized by Telos. Contact may be made via email: 

support@telosalliance.com

 

or via telephone: (+1) 216-241-7225. If Telos authorizes the performance of warranty service, 
the defective Product must be delivered to: Telos, 1241 Superior Avenue East, Cleveland, Ohio 
44114 or other company repair center as may be specified by Telos at the time of claim.

Shipping Costs and Warranty Service:

If the date the customer’s notice of warranty claim is received by Telos (such date the “

Warranty 

Claim Notice Date

”) is within the first 90 days following the Receipt Date, Telos will pay the 

costs of shipping such warranted Product to and from the end user’s location, and the cost of 
repair or replacement of such warranted Product.
If the Warranty Claim Notice Date occurs after the first 90 days following the Receipt Date and 
before the end of the second (2nd) year, the customer will pay the freight to return the war-
ranted Product to Telos. Telos will then, at its sole discretion, repair or replace the warranted 
Product and return it to the end user at Telos’ expense.  
If the Warranty Claim Notice Date occurs between the end of the second (2nd) year following 
the Receipt Date and the completion of the fifth (5th) year, the customer will pay the costs of 
shipping such warranted Product to and from the end user’s location. Telos will then, in its sole 
discretion, repair or replace the warranted Product at Telos’ expense.  Telos also reserves the 
right, if it is not economically justifiable to repair the warranted Product, to offer a replacement 
product of comparable performance and condition direct to the customer at a discounted price, 
accepting the failed warranted Product as a trade-in. 
The end user will in all cases be responsible for all duties and taxes associated with the shipment, 
return and servicing of the warranted Product.
No distributor, dealer, or reseller of Telos products is authorized under any circumstances 
to extend, expand or otherwise modify in any way the warranty provided by Telos, and any 
attempt to do so is null and void and shall not be effective as against Telos or its Affiliates.
Out of warranty units returned to the factory for repair may be subject to a $500 evaluation fee, 
which fee must be prepaid prior to shipping the unit to Telos. If no repairs are required, the $500 
fee will be retained by Telos as an evaluation charge. If repairs are required, the $500 fee will be 
applied to the total cost of the repair.

Summary of Contents for Volt

Page 1: ...air excitement and ultra clean sound in a versatile and convenient package MULTI USE AUDIO PROCESSOR INSTALLATION AND USERS GUIDE Software Version 1 0 FM DSP Core April 2017 For Part Number 2001 0043...

Page 2: ...the primary parts even when the fuse has blown If fuse replacement is required replace fuse only with same type and value for continued protection against fire WARNING The product s power cord is the...

Page 3: ...ce to tv or radio reception can occur if other devices are connected to this device without the use of shielded interconnect cables FCC rules require the use of shielded cables CANADAWARNING This digi...

Page 4: ...are deemed to have Your own direct license from the original licensee Telos does not modify these libraries in any way Telos hereby offers to You upon Your request and for the actual costs of materia...

Page 5: ...need your unit s serial number located on the back of the unit We will issue a return authori zation number which must be written on the exterior of your shipping container Please do not include cable...

Page 6: ...ate your coverage online at TelosAlliance com product registration TheTelos Alliance 1241 Superior Ave Cleveland OH 44114 USA 1 216 241 7225 For Omnia Support 24 7 telephone 1 216 622 0247 Email suppo...

Page 7: ...p 9 4 FrontPanelandLCD 14 Front Panel Meters 15 Using the JogWheel 16 VOLT Front Panel Menu Map 19 5 Browser basedRemoteControl 21 Logging In 21 Remote Screen 24 Remote Control Map 27 6 VOLTProcessing...

Page 8: ...types of broadcasters can excel in this ever evolving digital world Omnia Audio not only lets you stand out on the dial with your unique signature sound via legendary audio processors audio codecs an...

Page 9: ...r station a competitive exciting market leading sound that gets and holds listeners Now with Omnia VOLT we ve gone even further We ve rewritten the rules for broadcast DSP fine tuning our algorithms t...

Page 10: ...an extra hand on the clipper to stop distortion when the L R channel gets boosted by mono signals Omnia VOLT is fast setup and ease of use while giving you absolute control of every important paramet...

Page 11: ...ity baseband clipping to feed uncompressed STLs or at the transmitter with dual composite outputs Use VOLT for AM Broadcast with purpose built presets for the challenges of AM radio VOLT s Tunable Asy...

Page 12: ...ch input You can save and recall custom input output setups for different applications Switchable insert points for Voltair watermark encoders or other downstream encoding You can feed encoders with a...

Page 13: ...BU digital or Livewire sources They allow automatic failover signal switching if your main program source fails They let you insert watermark ID encoders and our Voltair watermark processor after your...

Page 14: ...you re using an audio input monitor transmitter or STL navigate to Input Output Output and adjust the appropriate Level for the next device Exit back to Input Output 7 Navigate to Output FM Options an...

Page 15: ...ys later Exit back to Main Menu 11 Navigate to Save Preset and provide a name for the settings you just created This can serve as a baseline while you do step 12 12 Read the rest of this manual Learn...

Page 16: ...on the air but break the lossy compression schemes in some STLs The result that the STL will create extra distortion and lack of clarity before the signal even gets to the transmitter This warning al...

Page 17: ...istributes the weight better Live studio VOLT does not have an internal fan and can be located near a live mic This makes our Multicast DSP Core version ideal for high quality podcasting and other sma...

Page 18: ...t don t have to be the same mode one can be analog for example while the other is AES EBU though this rarely occurs in practice Insert points are designated using VOLT s network Remote Control See tha...

Page 19: ...ions These are usable only if your VOLT is running an FM or FM Stereo Generator DSP Core Composite Outputs These are identical 75 outputs to feed a multiplex signal to your transmitter s Each is sepa...

Page 20: ...a 1k resistor If triggering from a logic source the source s continuous positive voltage should go to pin 2 and each output should pull its corresponding input pin low when active Systems using TTL le...

Page 21: ...m inal power is 1A at 110 V 5A at 240 V Actual consumption is around 15 watts during normal operation VOLT should be connected to a grounded outlet according to local codes VOLT does not have a power...

Page 22: ...w preset Headphone Gain Reduction Output LCD Jog Input level Wideband Individual Bands out volume AGC Limiter Mid MidHi Low MidLo Hi Mid MidHi Low MidLo Hi 11 Gate LEDs etc Composite Left Right Power...

Page 23: ...bottom LED of each stack lights when that section s Gate is activated There are 6 AGC meters wideband then the five individual frequen cy bands and 5 Limiter meters one for each frequency band About...

Page 24: ...three distinct ways Turn the wheel Rotating the wheel clockwise moves the highlighted selection on the LCD downward through menu options or to the right through fields where you can enter numbers or...

Page 25: ...hen your selected choice is highlighted tap the wheel to enter that submenu Or a screen might let you choose values like this one Mono Mode STEREO Input Mode LW Level 0 0dB Right Trim 0 0dB Invert Non...

Page 26: ...characters tap to confirm scroll to the next and so on When the complete name or number has been entered tap again to go to the next field Then don t tap again instead turn the wheel to select other...

Page 27: ...eo Mono L Mono R Mono L R Swap Exit Processing Menu Preset QuickTweak Save Preset Delete Preset Rename Preset Exit QuickTweak Menu Compr Depth 10 10 Density 10 10 Clip Drive 10 10 Lows 10 10 Highs 10...

Page 28: ...select Output on the submenu that appears tap the Jog Wheel then select and tap Tone Gen This is probably intuitive to anyone who s worked with modern digital gear Almost all of the functions shown a...

Page 29: ...d otherwise manage presets Upload CORE DSP functionality and firmware updates Perform system maintenance including network and password settings selection of running firmware and factory diagnostics P...

Page 30: ...assword Sophisticated IT users can configure the network to restrict access even with a password or extend a virtual network beyond your station s plant VOLT uses HTML5 without Java or other plug ins...

Page 31: ...are packages reboot the processorA and perform diagnostics when advised by our support team About Displays information about your system and Telos factory support Logout Clicking this tab disconnects...

Page 32: ...Con guration About Logout I O PROCESSING INPUT ANALOG AES LIVEWIRE COMPOSITE INITIAL AGC LIMITERS FINAL PRESETS BackEMF BigFuse CircuitBreaker Electra Fact_Test HotWire KILOWATT MEGAWATT SuperConduct...

Page 33: ...segment of each AGC meter will turn red when gating is engaged There s a rectangular button below each set of meters These activate a higher resolution version of the meter set on the left side of the...

Page 34: ...function names will be familiar to any broadcast engineer Some of the processing adjustments however are unique to VOLT They re described in the next chapter The next page is a reference map so you c...

Page 35: ...Efx Meters Pre proc HP Filter Freq Phase Rotator Voice Detect Voice Gain WB AGC Processing Active Bypass Drive Attack Release Accel Release Activity Gate Thresh RTZ Level RTZ Speed Enhancers Processin...

Page 36: ...nce VOLT uses to process your signal so you know which algorithms will be affected by the ones that come earlier VOLT terminology We ve used standard audio processing language whenever possible But we...

Page 37: ...ile actually lowering distortion Starting with the default setting for a preset adjust Drive down in 0 5 dB steps until the loudness drops just below what you want Then bring it up slightly from there...

Page 38: ...ou might want to get a bit deeper VOLT has more than 140 routing and processing settings Feel free to explore all of them in your search for sonic perfection And don t worry about making a mistake if...

Page 39: ...ement can help keep your stereo soundstage consistent and exciting across a variety of different recordings Take it in small doses Plan to do a little adjusting at a time perhaps in half hour segments...

Page 40: ...CHAPTER 6 32 VOLT PROCESSING...

Page 41: ...at 150 Hz compensating for some program material Be careful The Phat Bass warning applies Also the resonant frequency of many automobile interiors lies in this range too much warmth may sound tubby i...

Page 42: ...open sound even though the audio is still quite dense This also works in conjunction with the AGC s Gate Bass and Broadband Clippers Bass Tight Clip Hard clipper just on the bass notes to keep them f...

Page 43: ...00 AM 5 00 PM USA Eastern Time weekdays There s full contact information at the end of this chapter and at the end of this manual Features and operations of VOLT are determined largely by software Tel...

Page 44: ...n I O selections Input Output Composite Output impedance 75 single ended and floating over chassis ground BNC con nectors with EMI suppression Maximum cable 100 30M RG 58U Output level separately adju...

Page 45: ...gic levels 5 V and ground supplied Ethernet 10 100BaseTX Ethernet on EMI suppressed RJ 45 TCP IP control via HTML 5 internal web server password protected Manual addressing and port selection Electric...

Page 46: ...es ii has been improperly installed or misused including without limitation the failure to use telephone and power line surge protection devices iii has been damaged by accident or neglect As with all...

Page 47: ...iscretion repair or replace the warranted Product and return it to the end user at Telos expense If the Warranty Claim Notice Date occurs between the end of the second 2nd year following the Receipt D...

Page 48: ...1241 Superior Ave Cleveland Ohio 44114 USA 1 216 241 7225 TelosAlliance com 2017 TLS Corp All Rights Reserved C17 15050 P N 1490 00177 001 USER MANUAL OMNIA VOLT...