support@omnicomm-world.com | Installation manual Omnicomm 2.0 terminals v2.2
7
.16 | 66
APPENDIX H
Con
fi
guring Omnicomm Pro
fi
and Pro
fi
2.0 Terminals for installation at fuel stations
In order to install Omnicomm Pro
fi
and Pro
fi
2.0 Terminals, it is necessary:
To connect signal removal device (SRD) to the
fi
rst universal input of Omnicomm Pro
fi
or Pro
fi
2.0
Terminal.
Signal removal device (SRD) must be installed at fuel stations, equipped with motor fuel dispensing
counters manufactured by JSC “Prompribor” (Livny City).
Signal removal devices (SRD), supplied by Omnicomm, are signal removal devices SRD-B-70, manufactured
by JSC “Prompribor” and additionally equipped with connectors.
Signal removal devices SRD-B-70 can be purchased directly from the manufacturer or previously installed
SRD can be used. It is, however, necessary to observe the requirements for using of a connection cable
between the signal removal device (SRD) and the Terminal.
Attention!
When installing Omnicomm Pro
fi
or Pro
fi
2.0 terminal at fuel stations, it is necessary to connect
the power supply via the module of galvanic isolation, for example, via Omnicomm BR-15 (Figure 65).
Set the mode of the
fi
rst universal input as “impulse” and enter the calibration coe
ffi
cient value
Select “Impulse” operating mode in the “
Inputs”
section of Omnicomm Con
fi
gurator.
FIGURE 97
Enter the value of calibration coe
ffi
cient, depending on the model of Signal Removal Device and fuel meter
according to Table 3.