5) Dispense 10–20 l of fuel, and record the exact amount of dispensed fuel;
Important!
The entire volume of the fuel must be dispensed within the interval of a single data collection
timer. If unsuccessful, the data collection timer duration interval must be increased.
6) Record the number of impulses counted by the Terminal during the fuel dispensing process,
which is displayed in the “Current value at input”
fi
eld upon expiration of data collection timer
duration interval;
7) Calculate calibration coe
ffi
cient
K
using the following formula:
8) Set the desired timer data collection and the calibration coe
ffi
cient, then record the settings in
the Terminal.