background image

Omnicomm OBDII Terminal

User Manual
24.05.2019

Summary of Contents for OBDII

Page 1: ...Omnicomm OBDII Terminal User Manual 24 05 2019 ...

Page 2: ...n 10 Omnicomm Configurator 11 Remote Configuration Server RCS 12 SMS Commands 12 Commands Format 12 System Commands 14 Settings 22 Parameter Setting Request 32 Current Values Request 36 Event Notifications 39 Operation Parameters Setting 39 GPRS Connection 39 OBD Bus 40 OBD parameters tab to SAE J1979 SAE J1939 41 Connection to Communication Servers 42 Data Collection 43 ...

Page 3: ... 47 Internal Battery 47 Driving Safety Control 48 Service Functions 51 Terminal Reboot 52 Setting Password on Configuration Changing 52 Data Collection and Transmission Blocking 53 Remote Configuration Server Operation Setting 54 Terminal SIM Card Number Identification 54 Installation of a Protective Sticker 55 Sealing 55 Specifications 55 ...

Page 4: ...rough the OBDII connector driver sound alert VH impact logging driving safety control data storage in non volatile memory transferring data to Omnicomm Online or to third party software Installation SIM Card Inserting Before SIM card inserting disable PIN request at activation To this end insert the card in any cell phone and disable PIN request according to the cell phone operating instruction If...

Page 5: ...peed bus CAN Highspeed ISO 15765 4 SAE J2284 7 K Line ISO 9141 2 ISO 14230 8 Not used 14 CAN Low wire of the high speed bus CAN Highspeed ISO 15765 4 SAE J2284 15 K Line ISO 9141 2 ISO 14230 16 Battery power supply 12 24 V Terminal Connection Connect the terminal to the connector of vehicle s OBDII 5 General information ...

Page 6: ...he OBDII terminals should ensure a good radio coverage of the horizon If necessary use an OBD extension cable Setting Overview Omnicomm terminals may be configured in three ways 1 In the Omnicomm Configurator when the terminal is connected to a PC 2 In the Remote Configuration Server RCS remotely 3 By SMS commands 6 SettingOverview ...

Page 7: ...Servers Port 9977 Connection to Communication Servers Data collection timer 30 sec Data Collection Operation mode with ignition off and power on Collect data at jolting Collection all data is disabled Data Collection Data sending interval to CSin roaming 60 min Data Transmission to a Communication Server Adaptive data collection at cornering Enabled Data Collection Collecting data on the travelled...

Page 8: ...ission to a Communication Server The criterion for the connection of the terminal to the CS Data packet size to send to the CS Data Transmission to a Communication Server Data packet size to send to the CSin roaming 300 kB Data Transmission to a Communication Server Data packet size to send to the CSin roaming 300 kB Data Transmission to a Communication Server Ignition key status Voltage Threshold...

Page 9: ...ety Control Safe driving Speed Duration 15 Driving Safety Control Safe driving RPM 4000 Driving Safety Control Safe driving RPM Deviation 200 Driving Safety Control Safe driving RPM Duration 15 Driving Safety Control Sound notification Disabled Driving Safety Control Send SMSfor selected events Disabled Driving Safety Control Dangerous driving Acceleration threshold 0 2 g Driving Safety Control Da...

Page 10: ...eleration threshold 4 g Driving Safety Control Accident definition Disabled Driving Safety Control AUTOTILT Disabled Driving Safety Control OBDII parameters Not selected OBD Bus Setting name Default value User manual section Primary Activation Activate the OBDII terminal before the usage For terminal activation set the owner s phone to the terminal using SMS command pass tel yyyyyyyyyy or switch o...

Page 11: ...2 Install and run Omnicomm Configurator A window will open 3 Select equipment Terminal List of parameters shown in advanced mode only In the Communication section Data acquisition and transmission blocking Communication Server No 2 connection settings GSM and SMS communication parameters Roaming connection parameters Roaming parameters In the Auxiliary Equipment section 11 SettingOverview ...

Page 12: ...n server open the browser and in its address bar enter the address http config omnicomm ru A window will open To add terminals 1 In the Terminal ID field enter the terminal identification number 2 In the Password field enter the password set in the terminal during its setting using Omnicomm Configurator 3 Press the button SMS Commands Commands Format All commands sent not from the owner number mus...

Page 13: ...erminal setting must start with the owner telephone setup with the use of Omnicomm Configurator or SMS Command format Command head Password Command Command parameters Command end not mandatory field mandatory field not mandatory field Command example 3245 channel sms Command head Password Command Command parameters Command end 3245 channel sms 13 SettingOverview ...

Page 14: ...ssword will be required Default password 0000 The response is sent to the number which the command had been sent from Command text in SMS Comments Example pass tel yyyyyyyyyy pass password yyyyyyyyyy is the new number international format 20 characters maximum 1234 tel 79099091122 14 SettingOverview ...

Page 15: ...Changing Password Password can be changed only from the owner telephone Command text in SMS Comments Example pass xxxx xxxx new password Max 8 characters Latin letters numbers Password is case insensitive Default value 0000 pass 12345 Response to command Comments pass changed password was changed Potential Errors Comments pass Wrong owner number invalid owner number 15 SettingOverview ...

Page 16: ...s Example name NAME DEVICE password DEVICENAME device name up to 20 characters no spaces Latin letters digits symbols 1234 name SuperOBD_22 Response to command Comments name changed device name was changed Potential Errors Comments name Wrong pass Wrong password name Wrong name Only ASCII 20 symbols invalid name format 16 SettingOverview ...

Page 17: ...ments time changed to DD MM YYYY HH mm date and time were changed Potential Errors Comments time Wrong pass Wrong password time Wrong args invalid date and time format Enabling Disabling SMS Notifications Command text in SMS Comments Example SMS on SMS off on enabled off disabled 1234 SMSon Response to command Comments SMS on SMS off on enabled off disabled 17 SettingOverview ...

Page 18: ...Command text in SMS Comments Example net APN login password depends on mobile operator login password are optional 1234 net internet mts ru mts mts 1234 net internet mts ru Response to command Comments APN changed to ХХХ ХХХ set APN Potential Errors Comments net Wrong pass Wrong password net Wrong args invalid command format 18 SettingOverview ...

Page 19: ...esponse to command Comments server changed to CS address port protocol settings were changed Potential Errors Comments server Wrong pass Wrong password server Wrong args invalid command format Terminal Reboot Command text in SMS Comments Example restart terminal reboot 1234 restart Response to command Comments restart ОК terminal was restarted 19 SettingOverview ...

Page 20: ...onfiguration Server Command text in SMS Comments Example update connecting to the RCS 1234 update Response to command Comments update started Potential Errors Comments update Wrong pass Wrong password Resetting to Defaults Command text in SMS Comments Example default settings 1234 default settings 20 SettingOverview ...

Page 21: ...Response to command Comments reset settings ОК reset to default settings is completed Potential Errors Comments reset settings Wrong pass Wrong password 21 SettingOverview ...

Page 22: ...erval for data within the home network min Default value 10 YYYY sending interval for data in roaming 0 sending is not performed Z min sending data in roaming by time k sending data in roaming by package size Default values ХХХХ 10 min YYYYmin 0 min period 100 150k period 50 150min period 1000 0 22 SettingOverview ...

Page 23: ...etwork min YYYY data package size to be sent in roaming kB XXXX data sending interval in the home network min roaming disabled Potential Errors Comments period Wrong pass Wrong password period Wrong args invalid command format Setting the Data Collection Interval Command text in SMS Comments Example interval XXXX XXXX data collection sec 0 collection sending blocking timer value remains unchanged ...

Page 24: ...ong password interval Wrong args invalid command format Setting Fuel Tank Volume Command text in SMS Comments Example volume XXX XXX tank volume l Possible options from 0 to 65000 volume 100 Response to command Comments volume changed to XXХ XXX tank volume l Potential Errors Comments volume Wrong pass Wrong password volume Wrong args invalid command format 24 SettingOverview ...

Page 25: ... speed voltage rpm fuel rate temp key engine speed speed voltage voltage of the on board power supply rpm engine RPM fuel volume of fuel in the tank l rate fuel consumption rate temp oil temperature key ignition engine error indications Check Engine off disable sending of all parameters obd speed fuel and obd off Response to command Comments obd speed on fuel on obd Disable all only those paramete...

Page 26: ... OBD Terminal Command text in SMS Comments Example remove on remove off on enabled off disabled remove on remove off Response to command Comments remove on remove off on enabled off disabled Potential Errors Comments remove Wrong pass Wrong password remove Wrong args invalid command format 26 SettingOverview ...

Page 27: ...his time The command is sent with the only one parameter Command text in SMS Comments Example autotilt X Х sensitivity off no sending performed on sending enabled 1 low 9 high If the command is sent without parameters the mode will be enabled with the present sensitivity Default value 5 autotilt on Response to command Comments autotilt onX autotilt SMS on autotilt SMS off Х sensitivity off no send...

Page 28: ...f danger acc 5 or acc onor acc off danger turn5 or turnonor turnoff danger brake 5 or brake on or brake off danger vertacc 5 or vertacc onor vertacc off activation of dangerous driving control disabling dangerous driving control enabling SMSnotifications by preset parameters disabling SMSnotifications by preset parameters setting acceleration threshold setting lateral acceleration threshold settin...

Page 29: ...s on danger sms off danger acc on 5 danger brake off dangerous driving control enabled SMSnotifications enabled SMSnotifications disabled acceleration threshold control enabled and set equal to 5 braking threshold control disabled 29 SettingOverview ...

Page 30: ...rashoff crashsms on crashsms off crashacc X crashturnX crashbrake X enabling crash control disabling crash control enabling SMSnotifications by preset parameters disabling SMSnotifications by preset parameters setting acceleration threshold setting lateral acceleration threshold setting braking threshold X threshold values from 1 low to 9 high crash on crash sms off crash acc 1 crash turn 1 crash ...

Page 31: ...ash sms on crash sms off crash acc on 5 crash brake off crash control enabled SMSnotifications enabled SMSnotifications disabled acceleration threshold control enabled and set equal to 5 braking threshold control disabled 31 SettingOverview ...

Page 32: ... HW Dev YYYYYY time DD MM YYYY HH mm XXXXXXX firmware version DD MM YYYY HH mm device time Requesting Command Info Command text in SMS Comments Example Requesting Command List Response to command Comments help info period interval volume obd remove autotilt danger crash balance dervice gps list of commands without parameters 32 SettingOverview ...

Page 33: ... to command Comments period home XXXXmin roamYYYYmin XXXX data sending interval in the home network min YYYY data sending interval in roaming min Requesting Preset Data Collection Interval Command text in SMS Comments Example interval interval Response to command Comments interval XХХХ XXXX data collection interval s 33 SettingOverview ...

Page 34: ...Requesting Preset Fuel Tank Volume Command text in SMS Comments Example volume volume Response to command Comments volume XXX XXX fuel tank volume l 34 SettingOverview ...

Page 35: ...sting OBD Parameters Sent Command text in SMS Comments Example obd obd Response to command Comments obd speed X voltage X rpmX fuel X rate X temp X key X engine X Х on enabled off disabled 35 SettingOverview ...

Page 36: ...de that depends on operator balance 102 Response to command Comments balance ХХХ ХХХ current balance of the active SIM Mileage After Error Reset km Command text in SMS Comments Example service service Response to command Comments service distance XXXX time YYYY XXXX mileage after error reset km 36 SettingOverview ...

Page 37: ...X speed YYY point ZZZZ NNNN X number of satellites YYY speed ZZZZ NNNN coordinates in the URL form GPS sats 5 speed 69 point http google com maps q 55 7885 37 5891 Potential Errors Comments GPS No valid data GPSdata not obtained Requesting Current OBD Parameters Command text in SMS Comments Example obd obd 37 SettingOverview ...

Page 38: ...Response to command Comments obd current values current values are displayed depending on settings Fuel volume of the fuel tank volume Volume format depends on the vehicle type 38 SettingOverview ...

Page 39: ...nger current date and time GPS coordinates inthe URL form dangerous driving crash crash current date and time GPS coordinates inthe URL form accident crash Operation Parameters Setting GPRS Connection In the Settings tab select the Connection section from the list In the GPRSSettings section Access Point Name APN enter the GPRS access point name VimpelCom Beeline internet beeline ru 39 OperationPa...

Page 40: ...in and password for APN access point Login and password are provided with the SIM card of a number of mobile network operators OBD Bus In the Settings tab select the OBD section from the list In the OBDParameters section Default OBDII parameters are not selected From the list of parameters choose the ones you wish to display the value of in Omnicomm Online and check the corresponding boxes List of...

Page 41: ... from the terminal OBD parameters tab to SAE J1979 SAE J1939 Parameter Protocol SAEJ1979 SAEJ1939 SID PID PGN SPN Check Engine Error 0 01 0x01 FECA 1213 Revolutions rpm 0 01 0x0C F004 190 Speed km h 0 01 0x0D FEF1 84 Fuel volume 0 01 0x2F FEFC 96 Mileage after Maintenance km 0 01 0x31 Coolant temperature С 0 01 0x05 FEEE 110 Voltage V 0 01 0x42 FEF7 168 41 OperationParameters Setting ...

Page 42: ...roup defining the contents of the corresponding message according to SAE J1939 SPN code of the parameter according to SAE J1939 Connection to Communication Servers In the Settings of connection to thecommunication server sections CS 1 IP address or domain name enter IP address or domain name of the communication server cs dc1 omnicomm ru Port enter port to be used by terminal to connect to the com...

Page 43: ... data Collect data at jolting monitoring the status of the accelerometer If the accelerometer reading changes by more than 0 2 g the terminal switches to the Collect all data and performs data transmission to the Communication Server in 5 minutes Selecting Collect data at jolting set the following configuration Collect all data when this parameter is enabled the terminal upon expiration of the tim...

Page 44: ...ch the data will be collected Possible values 10 to 1000 meters Default value 100 meters Default value disabled Coordinate drift filtering enable to eliminate drift of coordinates during the Track report generation When enabling the Coordinate drift filtering the following settings are available Delay after ignition on s Default value 35 s Possible values 0 to 900 Maximum travel speed km h Default...

Page 45: ...elect the criterion for the connection of the terminal to the CS By time period or By packet size Default value Interval of sending data to the CS Interval of sending data to the server enter the number of minutes upon expiration of which the terminal must establish connection with the communication server while being in roaming Recommended value 180 minutes Default value 60 min Data packet size t...

Page 46: ...r data to two communication servers select In roaming as at home Selection of Ignition Source In the Settings tab select the Inputs section from the list In the Ignition keystatus section Data source select the data to register ignition on off Onboard voltage the ignition on is registered upon reaching the vehicle network power supply threshold voltage Threshold voltage value when this value is re...

Page 47: ...olume L enter the fuel tank volume Default value 100 L Current fuel volume L displays the current volume of fuel in the tank The current fuel volume is calculated at the terminal based on the data acquired via the OBD bus and the set tank volume Internal Battery In the Settings tab select the Auxiliaryequipment section from the list In the Internalbatteryparameters section Use internal battery ena...

Page 48: ...ect the accelerometer calibration mode Possible options automatic calibration manual calibration Prior to performing the calibration firmly fix the terminal and do not change its position during operation Automatic calibration is recommended for vehicles that are operated mainly at speeds above 50 km h Automatic calibration takes between 2 minutes and 24 hours depending on the frequency of acceler...

Page 49: ...on should not be more than 5 degrees In the Settings tab select the Driving Control section from the list Dangerous driving control enable disable registration of dangerous driving when exceeding the set values of monitored parameters 49 OperationParameters Setting ...

Page 50: ... 300 s Default value 15 s Engine speed RPM engine RPM monitoring Threshold enter the maximum permissible engine RPM upon exceeding which dangerous driving will be registered Possible values 0 to 10 000 rpm Default value 4 000 rpm Deviation enter the RPM value that can be exceeded by maximum permissible RPM without registration of violation Possible values 0 to 1000 rpm Default value 200 rpm Durati...

Page 51: ...h exceeding will trigger registration of dangerous driving Send SMS for selected events enable SMS sending upon registration of dangerous driving Determineaccidents enable disable accident registration upon exceeding the set values of monitored parameters Speeding up threshold value of acceleration while speeding up which exceeding will trigger registration of accident Lateral acceleration thresho...

Page 52: ...o use a password to configure the terminal settings in the field Ask for password when saving settings select Enabled Default value disabled Press the Record into device button A window will open New password and Confirm new password enter a new password that will be used to get access to settings configuration The password shall contain 8 characters maximum Press the Save button A window will ope...

Page 53: ...onnection section from the list In the Datacollection and transmission blocking section To block the terminal data collection and transmission in the Lock field select Enabled To unlock data collection and transmission use Omnicomm Configurator or send SMS command UNBLOCK to the SIM card inserted in the terminal 53 Service Functions ...

Page 54: ...88 terminal ID 12345 password to be set The password shall contain 8 characters maximum and may include any digits and letters The previously set password cannot be changed in this way After 6 hours the terminal will be authorized on the Remote Configuration Server and will be available for operation via the Remote Configuration Server Terminal SIM Card Number Identification The terminal SIM card ...

Page 55: ...picture Sealing Stick the sealing sticker on the connector so that the terminal cannot be switched off without breaking the sticker Specifications Omnicomm OBDII Communication Satellite Navigation Systems GLONASS GPS Data transmission channel GPRS Number of SIM cards and SIM chips 1 SIM card SIM chip available No 55 Installationof a Protective Sticker ...

Page 56: ...y events 150 000 Interfaces CAN interfaces Protocols ISO 15765 4 SAE J2284 J1939 J1979 USB interfaces Yes Built in accelerometer Yes Design Dimensions mm 50 8 х 46 5 х 23 5 Degree of enclosure protection IP52 only when using a protective sticker Operating temperature range С 40 85 Capabilities Omnicomm OBDII Communication 56 Installationof a Protective Sticker ...

Page 57: ...Remote control through GPRS Yes SMSnotifications Yes Omnicomm OBDII Communication 57 Installationof a Protective Sticker ...

Page 58: ...info omnicomm world com www omnicomm world com ...

Reviews: