OM100, OM300 & OM500 – QUICK REFERENCE GUIDE
Page 4 of 6
To program the System in the Command Mode:
1. Enter Master or Submaster Code
(Press and Release CL Key to Extend Time-out to 1 Minute)
2. Enter Command from Below (Where Indicated with CL, Press and Hold CL
Key Until Lights Flash Result)
3. Repeat Step 2 as Required or Enter 000 when done
- Single Red Light Indicates Invalid or Unrecognized Command Sequence -
Function
Command Sequence
Lights
Command Result
Add or Change
Code
ID + PIN + CL
G
R-R
Code added
Code already in use
Hold Code
86 + ID + CL
R-R-R
Code placed on hold
Restore Code
87 + ID + CL
G
G-G
R-R
Code restored
Supervisor restored
Code already in use
Supervisor
Privileges
88 + ID + CL
G-G
R
Assigned
Invalid ID
Manager
Privileges
89 + ID + CL
G-G-G
R
Assigned
Invalid ID
ID Status Inquiry ID + CL
G
G-G
G-G-G
G-R
G-G-R
G-G-G-R
R-R-R
User code in use
Active Supervisor code
Active Manager code
User code on hold
Supervisor code on hold
Manager code on hold
Code ID unassigned
Set Access
Level
90 + Level + CL
(Level = 1-Unlocked,
2-Code Required, 3-
Lockout or 4-Shutdown)
To set Level 1 to unlock
with first code, continue to
hold the CL key until a
second green flash
appears, (about. 1.5
seconds).
G
G-G
G-G-G
G-G-G-G
R-R
G----G
Unlocked level set
Code Required set
Lockout set
Shutdown set
Invalid access level
Unlocked after first valid code
Enable User
Groups
91 + CL
G
G-G
R-R
Groups enabled
Groups enabled & unsupervised
Invalid group number
Disable User
Groups
92 + CL
G
R-R
Groups disabled
Invalid group number
Service Code
Time Limit
94 + HH + MM + CL
G
R-R
Time limit set
Invalid time limit
Menus
99
N/A
* Requires printer
Code ID Number Ranges:
001 - 100; 300 or 500 General User / Extended User Codes
501 Master Code
502 - 509 Submaster Codes
510 Service Code
511 Audit Code