80-J4866-2 Rev. G
MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
12-17
System Verification
Basic MCP100 System Verification Procedure
5.
Go to the Home screen and tap the
System
icon. Tap the
System
tab.
Check the System Status field and verify that
the Status is Good.
• If the Status is Good, go to
• If the Status is a numerical value, go to the
appropriate diagnostic procedure for that
value in the
MCP100 Diagnostic Guide.
6.
Check the Database State field and verify that
it is SyncComplete. This may take up to 10
minutes.
• If the Database State is SyncComplete, go
to
• If the Database State is Out of Sync,
perform the diagnostic procedure in
Chapter 13 in the
MCP100 Diagnostic
Guide.
7.
Check the signal strength.
Tap the SDM tab. The FL C/No value should
be greater than 50; the RL C/No value should
be greater than 33.
• If the C/No values are in a high range, go to
• If the C/No values are in a low range,
perform the diagnostic procedure in
Chapter 8 in the
MCP100 Diagnostic
Guide.
Tap the OVT/CDMA tab. Check the RSSI
value on the screen. The
desired
RSSI value
should be less than 105.
• If the RSSI value is less than 105, go to
• If the RSSI value is greater than 105,
perform the diagnostic procedure in
Chapter 9 in the
MCP100 Diagnostic
Guide.