80-J4866-2 Rev. G
MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
12-13
System Verification
Flowchart—Basic MCP100 System Verification
Flowchart—Basic MCP100 System Verification
Turn ignition
ON
Step 2
Yes
Move unit to
acquire
network
signal
Step 1
OME-0093-101QMCP
Step 3
Does
MDU light up
& display characters?
Do backlight, volume,
and brightness
work?
See Chapter 5
in the
Omnitracs MCP
Diagnostic Guide
No
Status: GOOD
Status: ####
See appropriate
chapter in the
Omnitracs MCP
Diagnostic Guide
Display
System screen.
Does Status display
numerical code
or Good?
Step 5
OFF
within 10 minutes
Step 4
Check
NO SIGNAL light
Still ON
after 10 minutes
Step 6
See Chapter 12
in the
Omnitracs MCP
Diagnostic Guide
Check
Database State.
Is database out of
sync or sync
complete?
Out of Sync
SyncComplete
Go to Step 10
Mode: No Fix
Not incrementing
Mode: 3-D or 2-D
Incrementing
Display
GPS screen. Is
Mode 3-D or 2-D / Last
Update incre-
menting?
Step 8
See Chapter 10
in the
Omnitracs MCP
Diagnostic Guide
Display
Battery screen.
Touch the Test Battery
button. Are test
results good?
Battery: Good
Battery: Bad
See Chapter 17
in the
Omnitracs MCP
Diagnostic Guide
Call Omnitracs
Customer
Support
FOR TERRESTRIAL
Still Flashing
after 10 minutes
Step 9
See Chapter 6
in the
Omnitracs MCP
Diagnostic Guide
Step 7
See Chap 8 for
satellite or Chap 9
for terrestrial in the
Omnitracs MCP
Diagnostic Guide
Check
signal strength.
Is signal strength
okay?
FOR SATELLITE
Low C/no values
FOR TERRESTRIAL
RSSI >105
Status: GOOD