1.0

INTRODUCTION

1.1

General Description

The 6540-FK is the direct replacement for the discontinued FlexSwitch Model
600XC 2Fx + 2U.  The 6540-FK replacement kit consists of two iConverter
10/100Base-Tx to 100Base-Fx Media Converter Modules  installed in a iConverter
2-Module chassis.

The 6540-FK provides two 10/100 auto-negotiating UTP ports with auto-crossover
and two 100Base-Fx fiber ports.

The two 100Base-Fx fiber ports support half or full duplex operation.

The 6540-FK features front panel accessible DIP-Switches for convenient
configuration of the single UTP and fiber port.  On-board DIP-Switches
configure the link mode and backplane operation.  The backplane is enabled
by default.

1.2

Chassis Models

FlexSwitch Replacement Matrix

Discontinued Part

Replacement Part

6540-0

6540-0-FK

6540-2

6540-2-FK

6540-3

6540-3-FK

6541-0

6541-0-FK

6541-2

6541-2-FK

Replacement Matrix

FlexSwitch Model 6540

Fiber Type

Distance

Connector Type

SC

ST

MM

5km

6540-0-FK

6541-0-FK

SM

30km

6540-2-FK

6541-2-FK

SM

60km

6540-3-FK

-

Model Numbers

Page 3

Summary of Contents for FlexSwitch 6540-FK

Page 1: ...FlexSwitchTM 2Fx 2U Model 6540 FK Replacement Kit User Manual 140 Technology 500 Irvine CA 92618 Phone 949 250 6510 Fax 949 250 6514...

Page 2: ...ion 4 2 3 Fiber Installation 4 2 4 UTP Installation 4 3 0 CONFIGURATION 5 3 1 AC Site Preparation 5 3 2 AC Powered Chassis Mounting 5 3 3 Configuring the DIP Switches 6 3 3 1 Media Converter Modules F...

Page 3: ...pport half or full duplex operation The 6540 FK features front panel accessible DIP Switches for convenient configuration of the single UTP and fiber port On board DIP Switches configure the link mode...

Page 4: ...Converter 2 Module chassis with the backplane enabled on both modules and Link Segment selected If the modules are removed carefully slide the module into the open slot Align the module with the insta...

Page 5: ...If installed in a closed or multi module rack assembly the operating ambient temperature of the rack must not exceed the maximum rated 50 degrees C Installation of the equipment should be such that th...

Page 6: ...he UTP AN Man DIP Switch is in theAuto Negotiate AN position factory default the converterAuto Negotiates and matches the 10 100 speed and duplex mode of a mating Auto Negotiating device connected to...

Page 7: ...te Fault Detect RFD DIP Switch is in the UP position the RFD mode is selected When in the DOWN position factory default the RFD mode is disabled Note Connecting two converters with both set to RFD mod...

Page 8: ...On Module has power Fiber FDX Green Fiber in Half Duplex On Fiber in Full Duplex Fiber Lk Act Green No Fiber Link On Fiber Link is Active Blinking Data Activity UTP AN Green UTP is in Manual Negotiat...

Page 9: ...ode 50 125 62 5 125 100 140um Singlemode 9 125um UTP Connector Type RJ45 Fiber Connector Type Dual Fiber ST SC DIP Switches Fiber FDX HDX UTP AN MAN 10 100 FDX HDX Link Modes LS LP RFD Power Requireme...

Page 10: ...nal will continue to propagate through to the next port in the network A loss of link on the UTP port will cause the fault to propagated forward causing the fiber and UTP ports at the remote end to dr...

Page 11: ...y period Omnitron will at its option repair or replace a product which is proven to be defective For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omn...

Page 12: ...ntact Omnitron Technical Support Phone 800 675 8410 949 250 6510 Fax 949 250 6514 Address Omnitron Systems Technology Inc 140 Technology Dr 500 Irvine CA 92618 Email support omnitron systems com URL h...

Reviews: