background image

38 Tesla, Irvine, CA 92618 USA

Phone: (949) 250-6510

iConverter

®

1-Module Redundant Power Chassis

User Manual

General and Copyright Notice

This publication is protected by U.S. and international copyright laws. All rights reserved. 

The whole or any part of this publication may not be reproduced, stored in a retrieval 

system, translated, transcribed, or transmitted, in any form, or by any means, manual, 

electric, electronic, electromagnetic, mechanical, chemical, optical or otherwise, without 

prior explicit written permission of Omnitron Systems Technology, Inc.
The following trademarks are owned by Omnitron Systems Technology, Inc.: FlexPoint

TM

FlexSwitch

TM

, HybridNID

®

, iConverter

®

, miConverter

TM

, NetOutlook

®

, OmniLight

®

OmniConverter

®

, RuggedNet

®

, Omnitron Systems Technology, Inc.

TM

, OST

TM

 and the 

Omnitron logo. 
All other company or product names may be trademarks of their respective owners.
The information contained in this publication is subject to change without notice. 

Omnitron Systems Technology, Inc. is not responsible for any inadvertent errors.

Warranty

This network product and the included AC/DC power adapter are warranted to the 

original purchaser (Buyer) against defects in material and workmanship for a period of 

two (2) years from the date of shipment. The warranty for the network product can be 

extended to lifetime by registering the product at www.omnitron-systems.com/support 

within ninety (90) days from the date of shipment. During the warranty period, Omnitron 

will, at its option, repair or replace a product which is proven to be defective with the 

same product or with a product with at least the same functionality.
For warranty service, the product must be sent to an Omnitron designated facility, at 

Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s 

designated US address using Omnitron’s standard shipping method.

Limitation of Warranty

The foregoing warranty shall not apply to product malfunctions resulting from improper 

or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied 

equipment,  Buyer-supplied  interfacing,  unauthorized  modifications  or  tampering 

with equipment (including removal of equipment cover by personnel not specifically 

authorized and certified by Omnitron), or misuse, or operating outside the environmental 

specification of the product (including but not limited to voltage, ambient temperature, 

radiation, unusual dust, etc.), or improper site preparation or maintenance.

No other warranty is expressed or implied. Omnitron specifically disclaims the implied 

warranties of merchantability and fitness for any particular purpose.

The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron 

shall not be liable for any direct, indirect, special, incidental, or consequential damages, 

whether based on contract, tort, or any legal theory.

Environmental Notices

The equipment covered by this manual must be disposed of or recycled in accordance 

with the Waste Electrical and Electronic Equipment Directive (WEEE Directive) of 

the European Community directive 2012/19/EU on waste electrical and electronic 

equipment (WEEE) which, together with the RoHS Directive 2015/863/EU, for electrical 

and electronic equipment sold in the EU after July 2019. Such disposal must follow 

national legislation for IT and Telecommunication equipment in accordance with the 

Page 2

Summary of Contents for iConverter 8245-11pt

Page 1: ...oduct with at least the same functionality For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to product malfunctions resulting from improper or inadequat...

Page 2: ...ptions and variety of power connection types By utilizing the optional RJ 45 ports the chassis can be powered from a connected Power Sourcing Equipment PSE Optional contact closure sensors are provided for connection to external alarm indicators By installing a managed iConverter module into the chassis the chassis functions can be remotely managed by Telnet and SNMP software such as Omnitron s Ne...

Page 3: ...ultiple redundant load sharing power configurations The power is connected to the back of the chassis with connectors labeled Pwr1 and Pwr2 Pwr1 is the primary power connection and Pwr2 is the backup There are four primary power options and two backup options The combinations of primary and backup power include low voltage barrel connector low voltage terminal high voltage terminal and PoE from th...

Page 4: ...ing a three conductor insulated wire not supplied with 12AWG to 14AWG thickness Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the ground wire to the ground terminal on the chassis by fastening the stripped end to the DC power connector ground Connect the power cables to the chassis by fastening the stripped ends to th...

Page 5: ...such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elsewhere The DC supply source is to be located within the same premises as this equipment There shall be no switching or disconnecting devices in the earthed ...

Page 6: ...nector has the following pin configuration Pin Description Closed Open 1 Sensor 1 No Alarm Alarm 2 Signal Return RT 3 Sensor 2 No Alarm Alarm 4 Signal Return RT Sensor 3 No Alarm Alarm Signal Return RT Sensor 4 No Alarm Alarm Signal Return RT Contact Closure Sensors Pinout Configuration LED Indicators The following table details the LED status indicators LED Function Legend Color OFF State ON Blin...

Page 7: ...can only by configured from the Module Screen options Select the appropriate option to change the DIP switch setting The Module Screen also provides access to the status and control screen To select the Status Screen enter S For models with UTP ports the Control Screen is available to enable or disable Port A and Port B To select the Control Screen enter C Applications Battery Backup with Alarms W...

Page 8: ...y 5 and higher Sensors 16 to 24 gauge AC Power Requirements AC Adapter 100 240VAC 50 60Hz 0 2A 120VAC typical DC Power Requirements DC Input Terminal Block 9 24VDC 1 5A 9VDC typical 2 Pin Terminal non isolated DC Input Terminal Block 24 60VDC 0 3A 48VDC 3 Pin Terminal isolated DC Input AC Adapter 9 24VDC 1 5A 9VDC typical 2 5mm Barrel Connector DC Input PoE 44 57VDC 0 27A 48VDC typical RJ 45 Alter...

Reviews: