Contact Closure Sensor Configuration

The contact closures can be used to alert the network management system of problems 

associated with the remote location.  The contact closure sensor can also detect the 

opening and closing of a switch, such as a equipment door being opened or closed.  

The figure below illustrates this application.

Chassis Configured for Open Door Alarm

Specifications

Description

iConverter

 

1-Module Redundant Power Chassis

Standard 

Compliances

IEEE 802.3, 802.3af

Regulatory 

Compliances

UL, CE, FCC Class A, UKCA, 

AS/NZS 3548 and VCC1 Class A

Environmental

RoHS, WEEE and REACH

Management*

Telnet, SNMPv1, SNMPv2c, SNMPv3, Serial Console

Frame Size

Up to 1,536 bytes

Port Types

Copper:

10/100BASE-T (RJ-45)

Sensors:

4 Contact Closures (8-Pin Terminal)

Cable Types

Copper:

EIA/TIA 568 A/B, Category 5 and 

higher

Sensors:

16 to 24 gauge

AC Power 

Requirements

AC Adapter:

100 - 240VAC/50 - 60Hz

0.2A @ 120VAC (typical)

DC Power 

Requirements

DC Input:

(Terminal Block)

9 - 24VDC, 1.5A @ 9VDC (typical)
2-Pin Terminal (non-isolated)

DC Input:

(Terminal Block)

24 - 60VDC, 0.3A @ 48VDC
3-Pin Terminal (isolated)

DC Input:

(AC Adapter)

9 - 24VDC, 1.5A @ 9VDC (typical)
2.5mm Barrel Connector

DC Input:

(PoE)

44 - 57VDC, 0.27A @ 48VDC (typical)
RJ-45 (Alternative A & B)

Output Power

3A @ 3.3VDC (per power input)

Dimensions

(W x L x H)

5.4” x 6.8” x 1.0”  (137.16 mm x 172.72 mm x 25.4 mm)

Weight

Chassis:               1.5 lbs. (0.68 kg)
w/ AC Adapter:     2.0 lbs. (0.91 kg)

Temperature

Commercial:

Wide:

Storage:

   0 to 50°C
-40 to 60°C
-40 to 80°C

Humidity

5% to 95% (non-condensing)

Altitude

-100m to 4,000m (operational)

MTBF

(hours)

Chassis:                     540,000
US AC Adapter:         250,000
w/ Univ AC Adapter:  100,000

Warranty

Lifetime warranty with 24/7/365 free Technical Support

* Management is available when an iConverter module with integrated management (such as the 10/100M2) is installed in the 

chassis.

Page 15

Page 16

Summary of Contents for iConverter 8245-11pt

Page 1: ...oduct with at least the same functionality For warranty service the product must be sent to an Omnitron designated facility at Buyer s expense Omnitron will pay the shipping charge to return the product to Buyer s designated US address using Omnitron s standard shipping method Limitation of Warranty The foregoing warranty shall not apply to product malfunctions resulting from improper or inadequat...

Page 2: ...ptions and variety of power connection types By utilizing the optional RJ 45 ports the chassis can be powered from a connected Power Sourcing Equipment PSE Optional contact closure sensors are provided for connection to external alarm indicators By installing a managed iConverter module into the chassis the chassis functions can be remotely managed by Telnet and SNMP software such as Omnitron s Ne...

Page 3: ...ultiple redundant load sharing power configurations The power is connected to the back of the chassis with connectors labeled Pwr1 and Pwr2 Pwr1 is the primary power connection and Pwr2 is the backup There are four primary power options and two backup options The combinations of primary and backup power include low voltage barrel connector low voltage terminal high voltage terminal and PoE from th...

Page 4: ...ing a three conductor insulated wire not supplied with 12AWG to 14AWG thickness Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the ground wire to the ground terminal on the chassis by fastening the stripped end to the DC power connector ground Connect the power cables to the chassis by fastening the stripped ends to th...

Page 5: ...such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing of the DC system The DC system shall not be earthed elsewhere The DC supply source is to be located within the same premises as this equipment There shall be no switching or disconnecting devices in the earthed ...

Page 6: ...nector has the following pin configuration Pin Description Closed Open 1 Sensor 1 No Alarm Alarm 2 Signal Return RT 3 Sensor 2 No Alarm Alarm 4 Signal Return RT Sensor 3 No Alarm Alarm Signal Return RT Sensor 4 No Alarm Alarm Signal Return RT Contact Closure Sensors Pinout Configuration LED Indicators The following table details the LED status indicators LED Function Legend Color OFF State ON Blin...

Page 7: ...can only by configured from the Module Screen options Select the appropriate option to change the DIP switch setting The Module Screen also provides access to the status and control screen To select the Status Screen enter S For models with UTP ports the Control Screen is available to enable or disable Port A and Port B To select the Control Screen enter C Applications Battery Backup with Alarms W...

Page 8: ...y 5 and higher Sensors 16 to 24 gauge AC Power Requirements AC Adapter 100 240VAC 50 60Hz 0 2A 120VAC typical DC Power Requirements DC Input Terminal Block 9 24VDC 1 5A 9VDC typical 2 Pin Terminal non isolated DC Input Terminal Block 24 60VDC 0 3A 48VDC 3 Pin Terminal isolated DC Input AC Adapter 9 24VDC 1 5A 9VDC typical 2 5mm Barrel Connector DC Input PoE 44 57VDC 0 27A 48VDC typical RJ 45 Alter...

Reviews: