Contact Closure Sensor Configuration
The contact closures can be used to alert the network management system of problems
associated with the remote location. The contact closure sensor can also detect the
opening and closing of a switch, such as a equipment door being opened or closed.
The figure below illustrates this application.
Chassis Configured for Open Door Alarm
Specifications
Description
iConverter
1-Module Redundant Power Chassis
Standard
Compliances
IEEE 802.3, 802.3af
Regulatory
Compliances
UL, CE, FCC Class A, UKCA,
AS/NZS 3548 and VCC1 Class A
Environmental
RoHS, WEEE and REACH
Management*
Telnet, SNMPv1, SNMPv2c, SNMPv3, Serial Console
Frame Size
Up to 1,536 bytes
Port Types
Copper:
10/100BASE-T (RJ-45)
Sensors:
4 Contact Closures (8-Pin Terminal)
Cable Types
Copper:
EIA/TIA 568 A/B, Category 5 and
higher
Sensors:
16 to 24 gauge
AC Power
Requirements
AC Adapter:
100 - 240VAC/50 - 60Hz
0.2A @ 120VAC (typical)
DC Power
Requirements
DC Input:
(Terminal Block)
9 - 24VDC, 1.5A @ 9VDC (typical)
2-Pin Terminal (non-isolated)
DC Input:
(Terminal Block)
24 - 60VDC, 0.3A @ 48VDC
3-Pin Terminal (isolated)
DC Input:
(AC Adapter)
9 - 24VDC, 1.5A @ 9VDC (typical)
2.5mm Barrel Connector
DC Input:
(PoE)
44 - 57VDC, 0.27A @ 48VDC (typical)
RJ-45 (Alternative A & B)
Output Power
3A @ 3.3VDC (per power input)
Dimensions
(W x L x H)
5.4” x 6.8” x 1.0” (137.16 mm x 172.72 mm x 25.4 mm)
Weight
Chassis: 1.5 lbs. (0.68 kg)
w/ AC Adapter: 2.0 lbs. (0.91 kg)
Temperature
Commercial:
Wide:
Storage:
0 to 50°C
-40 to 60°C
-40 to 80°C
Humidity
5% to 95% (non-condensing)
Altitude
-100m to 4,000m (operational)
MTBF
(hours)
Chassis: 540,000
US AC Adapter: 250,000
w/ Univ AC Adapter: 100,000
Warranty
Lifetime warranty with 24/7/365 free Technical Support
* Management is available when an iConverter module with integrated management (such as the 10/100M2) is installed in the
chassis.
Page 15
Page 16