background image

1U 19” 

iConverter

® 

XM5 NID Rack Mount Shelf 

User Manual

PRODUCT OVERVIEW

The 8261-0 1U 19” XM5 Rack Mount Shelf accommodates two iConverter

®

 XM5 Network 

Interface Devices or two iConverter

®

 XM5-1G Network Interface Devices. 

1U Rack Mount Shelf

The shelf does not support the iConverter XM5 Aggregation Demarcation Device. 

INSTALLATION PROCEDURE

1) Unpacking, Visual Inspection and Inventory
2) Rack Mounting
3) General Installation
4) Installing iConverter XM5 NIDs to the Shelf

1) UNPACKING, VISUAL INSPECTION AND INVENTORY

Review the contents. The following items should be included:

• 

1U Rack Mount Shelf 

• 

User Manual

• 

Four (4) Mounting Brackets  

• 

Eight (8) #4-40 1/4” Flathead screws

2) RACK MOUNTING

Mount and attach the shelf to the 19” standard rack using the appropriate rack mounting 

screws (not included).
When rack-mounting the shelf, the rack should be appropriately earthgrounded.  The shelf 

provides NEBS ground posts to secure a grounding lug from the rack to the shelf.

Page 1

3) GENERAL INSTALLATION

Install the mounting brackets to the side of the XM5 using the supplied screws. 

iConverter XM5 NIDs with mounting bracket

Remove any rubber feet before installing the module/chassis to the shelf.

4)  INSTALLING ICONVERTER XM5 NIDS TO THE SHELF

Slide the XM5 into the mounting guide slots on the shelf.

Installing iConverter XM5 NIDs on the Shelf

Continue to slide the XM5 until it is flush with the front mount bracket on the shelf.  Secure 

the XM5 by fastening the thumbscrew (push in and turn clockwise to tighten) to the shelf.

XM5 NIDs Installed in the Shelf

Embedded cable tie down slots secure the power cord(s) and data cable(s) to the shelf 

(cable ties not included).

Page 2