10355010_V_1_0.DOC
10/10
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Input impedance:
47 kOhm
Output impedance:
12 kOhm
Gain:
-13 dB
Dimensions:
95 x 73 x 40 mm
Weight:
300 g
Please note: Every information is subject to change without prior notice. 03.06.2004 ©