Drainage sleeve suits to the majority of
drainage lines with the diameter of 40 mm. It
is recommended to install the sleeve on the
drainage line in front of the siphon.
Remove the protecting film from the gasket.
Stick the gasket to the inner side of the
sleeve so that the hole in the gasket
coincides with the hole in the fitting of the
sleeve.
Fix the sleeve on the drainage line and
tighten the screws. It is recommended to
tighten them evenly, to set the both parts of
the sleeve parallel to each other.
Perforate the hole with the diameter of 7 mm
through the fitting of the sleeve.
Put the plastic screw on the drainage pipe,
and after you insert the pipe into the
drainage sleeve, please twist the screw on
the fitting.
DRAINAGE SLEEVE INSTALLATION
The slit insert is optionally set in case if the
water is rich in mechanical impurities.
Extract the slit insert under the purifier’s
cover. To take off the cover, turn 3 fixers
counterclockwise.
Set the slit insert into the pipe 3/8” (9,5 mm)
and connect this jet to the purifier.
SLIT INSERT INSTALATION*
Set the bracket for the M-Complex 4 on the
decorative cover of the OMOIKIRI Pure drop
2.1.4S and fix it with the taptite.
Before the miniralizer M-Complex 4
installation pull locking plug out of the JG
pipe (look «How to connect the JG pipes» in
«OMOIKIRI Pure drop 2.1.4S Lounch»).
Set the mineralizer into the bracket by
pressing it.
Connect JG 1/4” white color (d=6,35 mm,
L=0,17 m) connector with OMOIKIRI Pure
drop 2.1.4S.
M-COMPLEX 4 INSTALLATION
ATTENTION!
Inserts are included into the
set: 1 is for installation,
2 others are reserve ones.
gasket
protecting
film
*The slit insert is set only in case of high
content of mechanical impurities in water.
slit insert
14