ATTENTION!
Do not drink the water
taken after the flushing.
Check the purifier for leaking during the first week of exploita-
tion. The noise can appear when switching the automatic valve.
It’s connected with the air going out from the inner cavities. This
is not a defect, and after some time the noise disappears.
M-Complex 5S installation
Extract service plug.
Delete the packaging film from module M-Complex 5S and shipping plugs (if
any given). Rinse the module sealing rings under water.
For convenience the locking push buttons of the collectors are varied in color
(black and red). Install M-Complex 5S in the following order: red locking
button — M-Complex 5S.
M-Complex 5S flushing
Open inlet valve. Turn on the clear water tap and wait until the water start to
flow.
Run the water through the system for 1 hour.
Turn off the clear water tap.
3. OMOIKIRI PURE DROP 2.1.4S FLUSHING
After filling of an accumulative tank (when water ceases to go from a drainage
pipe), open the tap for clear water and wait until all water flows out from an
accumulative tank
Fill the tank and drain the water again. The procedure of the second tank filling
may take about 3 hours.
Make sure the purifier is leak-tight.
After filling of a tank, the OMOIKIRI Pure drop 2.1.4S water purifier is ready to
use.
locking push
button
Replacement of the V-Complex 1
Turn off the inlet valve and turn on the clear water tap to depressurize the water.
Hold the locking push button (black), turn module V-Complex 1 counterclockwise and take it off.
Take the protecting film off the new module.
Rinse the sealing rings of the module under water.
Insert new module into the collector up to the stop position and turn the filtering module clockwise till it clicks, applying
some pressure on it.
Change module M-Complex 5S to the service plug.
Turn on the inlet tap and make sure the purifier is leak-tight.
Flush the module according to the present instruction.
Change the service plug to the M-Complex 5S back.
Replacement of the M-Complex 5S
Turn off the inlet valve and turn on the clear water tap to depressurize the water.
Hold the locking push button (red), turn module M-Complex 5S counterclockwise and take it off.
Take the protecting film off the new module.
Rinse the sealing rings of the module under water.
Insert new module into the collector up to the stop position and turn the filtering module clockwise till it clicks, applying
some pressure on it.
Turn on the inlet tap and make sure the purifier is leak-tight.
Flush the module according to the present instruction.
The service life of the M-Complex 5S membrane module directly depends on the working capacity of the V-Complex 1
filtering module. That is why it is important to replace it in time.
MODULES REPLACEMENT
16