Use OMOIKIRI Pure drop 2.1.4S water purifier for intended purpose only.
This water purifier in designed only for purification of cold water form centralized water supply systems.
Purified water is not subject for long term storage. Use fresh filtered water.
The purifier is designed for fining and softening water corresponding to the Sanitary Regulations and Norms
2.1.4.1074-2001 (Drinking water).
When installing the purifier outside the centralized water supply systems it is recommended to analyze the water for
Sanitary Regulations and Norms 2.1.4.1074-01 coincidence. If the water does not satisfy the requirements the lifetime of
the filtering module and the RO-membrane becomes lower. After the installation it is necessary to check the clear water
at least once a year. If the water does not satisfy the requirements it is necessary to apply to the maintenance organiza-
tion, because this water is undrinkable.
The reverse osmosis system can hinder bacteria and viruses which can be contained in the water, but it is recommended
to use the water system, which is safe in microbiological matter. Do not use the water with unknown quality or any water
that does not satisfy the requirements.
If environmental temperature has reached 38°С or higher, the water purifier should be turned off from the cold water
main until the temperature goes down.
If you know that the water purifier would not be used for 24 hours or more, turn off the inlet tap.
If you have not used the water purifier for more than 2 weeks, let water flow through it again.
Do not let the plastic pipes bend.
Do not let plastic pipes and water purifier touch hot water pipes.
Keep the water purifier clean.
It is forbidden to turn over, shock or hit the purifier. It is transported via all the types of closed vehicle.
Do not shock it or let it fall down and make sure water does not freeze in it.
Recycle according the ecological, sanitary and other requirements, set by the national standards in the field of
environmental care and providing sanitation-and-epidemiological security of the people.
PRECAUTIONARY MEASURES, STORAGE AND
TRANSPORTATION
Replacement of the M-Complex 4
Turn off the inlet valve and turn on the clear
water tap to depressurize the water.
Disconnect JG pipes from inlet and outlet
connector. Extract the locking clip under the
plastic fitting and after pressing on the end of
the plastic fitting, pull off the pipe.
Extract new module out from the holder. Take it
and forcefully pull it upwards. For installation
repeat your actions recursively.
Flush the module according to the present
instruction.
Replacement of the slit insert
Turn off the inlet valve and turn on the clear water tap to depressurize the water.
Take out the slit insert from the pipe and replace with new.
The procedure of flushing is not required to be carried out.
outlet locking plug
inlet locking plug
water direction
17