Serial Communication
68
ZG2-DSU User’s Manual
Acquire Number of Connected Devices <CHGET command>
This command acquires the number of gang-mounted Sensor Controllers and Data
Storage Units.
<Command format>
<Response format>
<Explanation of parameters>
Example of response
Parameter No.
0 (default): Total number is acquired.
1: Number of connected Sensor Controllers is acquired.
2: Number of connected Data Storage Units is acquired.
Parameter No.
Configuration
0
1
2
ZG2-DSU+ZG2-WDC+ZG2-WDC
3
2
1
ZG2-DSU+ZG2-WDC
2
1
1
ZG2-WDC+ZG2-WDC
2
2
0
ZG2-WDC
1
1
0
C H G E T
CR
Parameter No.
E R
CR
CR
When processing ends successfully
When processing fails
Number
Summary of Contents for 257553
Page 1: ...User s Manual Cat No Z289 E1 02 Smart Sensor Data Storage Unit ZG2 DSU...
Page 10: ...8 ZG2 DSU User s Manual MEMO...
Page 14: ...12 ZG2 DSU User s Manual MEMO...
Page 38: ...Loading Logging Data to an External Device 36 ZG2 DSU User s Manual MEMO...
Page 42: ...Transferring Bank Data to the Controller 40 ZG2 DSU User s Manual MEMO...
Page 52: ...Bank Functions 50 ZG2 DSU User s Manual MEMO...
Page 86: ...Updating the Firmware 84 ZG2 DSU User s Manual MEMO...
Page 89: ...6 APPENDICES INDEX 87 ZG2 DSU User s Manual MEMO...
Page 91: ......