Acquire Logged Profile <CFPRFGET command>
This command acquires the profiles saved on the Memory Card. The specified file is
received by XMODEM protocol.
This command can be used only when the Data Storage Unit is connected with the USB cable.
<Command format>
<File transfer>
The file is transferred by XMODEM (-CRC or -SUM) after READY is received. XMODEM
(-K) is not supported.
<Response format>
<Explanation of parameters>
Folder No.
Specify the folder No. with a 3-digit number.
File No.
Specify the file No. with a 3-digit number.
Measurement value
The acquired measurement value is returned.
Important
C F P R F G E T
0 0 1
0 1 1
CR
C F P R F G E T
CR
Folder No.
(max. 3 digits)
Example: To acquire the profile data of file No. 11 stored in folder No. 1
File No. (max. 3 digits)
O K
CR
D I R
N O
CR
N O F I L E
CR
R E A D Y
CR
When processing ends successfully
When processing fails
• When there is no data (file) corresponding to the specified logging No.
• When the Memory Card is not inserted
Summary of Contents for 257553
Page 1: ...User s Manual Cat No Z289 E1 02 Smart Sensor Data Storage Unit ZG2 DSU...
Page 10: ...8 ZG2 DSU User s Manual MEMO...
Page 14: ...12 ZG2 DSU User s Manual MEMO...
Page 38: ...Loading Logging Data to an External Device 36 ZG2 DSU User s Manual MEMO...
Page 42: ...Transferring Bank Data to the Controller 40 ZG2 DSU User s Manual MEMO...
Page 52: ...Bank Functions 50 ZG2 DSU User s Manual MEMO...
Page 86: ...Updating the Firmware 84 ZG2 DSU User s Manual MEMO...
Page 89: ...6 APPENDICES INDEX 87 ZG2 DSU User s Manual MEMO...
Page 91: ......