2JCIE-BL01 Environment Sensor User’s Manual (A278)
20
2.2.6
Pressure
(Characteristics UUID: 0x3017)
Barometric Pressure sensor related event settings
.
Table 21. Pressure format
Byte
Field
Format
Contents
0
Event Enable/Disable
UInt8
Bit 7-6 : RFU
Bit 5 : Simple threshold [lower limit]
Bit 4 : Simple threshold [upper limit]
Bit 3 : Changing trend [decline/term]
Bit 2 : Changing trend [rise/term]
Bit 1 : Changing trend [decline/previous]
Bit 0 : Changing trend [rise/previous]
Enable: 1, Disable: 0
Default
:
0x00
1
Changing trend threshold
[rise/previous]
L
SInt16
Unit
:
0.1 hPa
Range
:
0.1
~
200.0 hPa
Default
:
0x0032 (5.0 hPa)
2
H
3
Changing trend threshold
[decline/previous]
L
SInt16
4
H
5
Changing trend threshold
[rise/term]
L
SInt16
6
H
7
Changing trend threshold
[decline/term]
L
SInt16
8
H
9
Simple threshold
[upper limit]
L
SInt16
Unit
:
0.1 hPa
Range
:
700.0
~
1100.0 hPa
Default
:
0x2AF8 (1100.0 hPa)
10
H
11
Simple threshold
[lower limit]
L
SInt16
Unit
:
0.1 hPa
Range
:
700.0
~
1100.0 hPa
Default
:
0x1B58 (700.0 hPa)
12
H
13
Term for changing trend
(Number of Measurements)
UInt8
Unit
:
1 count
Range
:
1
~
8 count
Default
:
0x06 (6 count)
14
Moving average number
UInt8
Unit
:
1 count
Range
:
1
~
8 count
Default
:
0x01 (1 count)