2 - 15
2 CompoNet Communications Unit Mounting and Wiring
CompoNet Communications Unit User’s Manual (I582-E1)
2-2 In
stal
latio
n
2
2-
2-3 Oper
atin
g Environme
nt
13
When the required inverter parameters are set properly, remove the straight Ethernet
cable from the inverter.
Additional Information
For how to remove the CompoNet Communications Unit, refer to
For information on the installation environment, refer to Section 2 Design of the MX2 User's Manual
(Cat. No. I570) or RX User's Manual (Cat. No. I578). In addition to this, provide sufficient clearance to
allow connection and removal of the CompoNet connector. When connecting a cable, provide a suffi-
cient allowance to prevent it from being pulled or bent.
You can use several types of communications cables for CompoNet network. Choose a flat cable or
round cable that fits your application.
For how to connect cables and prepare/mount cable connectors, refer to Section 4 Installation and Wir-
ing of the CS/CJ-series CompoNet Master Units Operation Manual (W456).
CompoNet connector signals
Precautions for Correct Use
Precautions for Correct Use
The BS+ (communications power ) and BS- (communications power supply -) signals
are not used in the CompoNet Communications Unit, so no connections are necessary.
2-2-3
Operating Environment
2-2-4
Connector Wiring
Color
Signal
Description
Red
BS+
Communications power supply (24 VDC)
White
BDH
Communications data lines (High)
Blue
BDL
Communications data lines (Low)
Black
BS-
Communications power supply (0 VDC)
BS+
BDH
BDL
BS-
Summary of Contents for 3G3AX-MX2-CRT-E
Page 94: ...3 Network Startup 3 36 CompoNet Communications Unit User s Manual I582 E1...
Page 118: ...4 Remote I O 4 24 CompoNet Communications Unit User s Manual I582 E1...
Page 134: ...5 Message Communications 5 16 CompoNet Communications Unit User s Manual I582 E1...
Page 167: ...I 1 I CompoNet Communications Unit User s Manual I582 E1 Index...
Page 171: ......