76
Modbus Register Object (Class 0x64)
APPENDIX E
Example 1:
Reading single word
Modbus register
Parameter:Coil data 1 (address 1E01 Hex)
Command:
Response:
Please note the swapping of the data following CIP data type encoding.
Example 2:
Writing single word
Modbus register
Parameter:EEPROM Save parameter 0900 Hex (value 1 Hex)
Command:
Response:
Attr: Low byte register
Inst: High byte register
Class ID
Service code
Destination node address
01
0E
64
1E
Data
06
04
00
8E
Source node address
Number of bytes received
Service code
Service code
Destination node address
Class ID
00
10
64
09
01
00
Data
Attr: Low byte register
Inst: High byte register
90
Source node address
Number of bytes received
Service code
02