Unit Components and Specifications
SECTION 2
Item Specifications
Allocated to
Inverter
19 words (DM 2022 to DM 2040)
PLC Setup
56 words (DM 6599 to DM 6655)
Item Specifications
External
interrupts
2 bits (Used in common for input interrupt counter mode and high-
speed inputs.)
Interrupt
processing
Scheduled
interrupts
1 bit (Scheduled interrupts or one-shot interrupts)
Pulse outputs
2 bits (without acceleration/deceleration; 10 Hz to 10 kHz each; without
directional control).
Or 1 bit (with trapezoidal acceleration/deceleration; 10 Hz to 10 kHz
each; with directional control).
Or 2 bits (Variable duty ratio output).
Pulse synchronous control
1 bit
A high-speed counter can be combined with pulse output, and the
input pulse frequency from the high-speed counter can be multiplied by
a fixed factor for pulse output.
Pulse catch inputs
2 bits
Minimum pulse input: 50 µs max.
Used in common by input interrupts and input interrupt counter mode.
Analog volume
None
Input time constant
(ON response time =
OFF response time)
Only all inputs can be set.
(1 ms / 2 ms / 3 ms / 5 ms / 10 ms / 20 ms / 40 ms / 80 ms)
Clock function
Yes
Communication function
Port 1 = Peripheral and RS-422
Host Link, Peripheral bus, No-protocol, Programming
Console
Port 2 = RS-232C port:
Host Link, no-protocol, 1:1 PLC Link, 1:1 NT Link
Power-interruption hold function
Holds the contents of HR, AR, CNT, and DM Areas.
Non-volatile memory, User program, DM (Read only), PLC Setup
Memory backup
Fixed internal lithium battery (5 years, not replaceable by the user) or
capacitor
DM (Read/Write), HR, SR and CNT Areas
Self-diagnostic function
CPU errors, memory errors, communications errors, setting errors,
battery errors
Program check
No END instruction, program errors (regularly checked during
operation)
CX-Programmer
After Version 2.1
Programming
Console
C200H-PRO27, CQM1-PRO01
SSS
PC98 & PC/AT (SYSMAC Support Software, All version)
Connected
tools
Sysdrive
Configurator
After version 2
19
Summary of Contents for 3G3MV-P10CDT-E
Page 2: ...3G3MV P10CDT PLC Option Unit User s Manual Revised June 2003 ...
Page 38: ...Unit Components and Specifications SECTION 2 2 1 4 Dimensions 68 128 55 25 ...
Page 43: ......
Page 85: ...Example Programs Appendix B 72 ...
Page 86: ...Example Programs Appendix B 73 ...
Page 87: ...Example Programs Appendix B 74 ...
Page 88: ...Example Programs Appendix B 75 ...
Page 90: ...Example Programs Appendix B 77 ...
Page 91: ...Example Programs Appendix B 78 ...
Page 97: ...Example Programs Appendix B B 4 9 Programs User_Parameter_Init 84 ...
Page 98: ...Example Programs Appendix B 85 ...
Page 99: ...Example Programs Appendix B User_Application Pos_Loop 86 ...
Page 100: ...Example Programs Appendix B 87 ...
Page 101: ...Example Programs Appendix B 88 ...
Page 102: ...Example Programs Appendix B 89 ...
Page 103: ...Example Programs Appendix B 90 ...
Page 104: ...Example Programs Appendix B 91 ...
Page 105: ...Example Programs Appendix B 92 ...
Page 106: ...Example Programs Appendix B 93 ...
Page 107: ...Example Programs Appendix B Pos_Home_Sequence 94 ...
Page 108: ...Example Programs Appendix B 95 ...
Page 109: ...Example Programs Appendix B 96 ...