109
Program Example for Cumulative Gate Mode
Section 9-6
9-6
Program Example for Cumulative Gate Mode
This section explains a program example for a system using the High-speed
Counter Unit in cumulative gate mode.
Note
After writing a program, make sure that the program works properly.
System Configuration
Detecting Incorrectly Processed Products
Operation
This system detects incorrectly processed products.
Encoder inputs are counted while the photoelectric sensor is ON. After the
material is fed for a fixed length, the PC determines whether or not the length
is acceptable. External control inputs are used as control inputs. The count
value is reset when the mark is detected.
The value in the parentheses is for counter 2.
Offset phase inputs multiplied by 1 are input to the encoder.
BCD data is used in the system.
The counter is reset when external control input IN1 is turned ON.
C200H-CT021 High-speed Counter Unit
Use an Encoder Conversion
Adapter to connect line driver
outputs from an encoder with
open collector outputs.
Encoder
Conversion Adapter
Encoder inputs A, B
External control input IN1
Sensor
Mark: Used for detection
of fixed lengths of the
material.
Incremental
encoder
Sensor
External control input IN2
C200HX
External control
IN1
Present
counter value
Counting
Word n+6 bit 00 (08)
At PC
External control
IN2
Arithmetic
operation
Summary of Contents for C200H-CT021