7
.
Serial Communications Connection Procedure
14
4
Use the procedure on the right
to set the parameters as follows:
C071 (Communication Speed
Selection): 05 (9600bps)
03: 2400bps
07: 38.4kbps
04: 4800bps
08: 57.6kbps
05: 9600bps
09: 76.8kbp
06: 19.2kbps
10: 115.2kbps
c001
Press the
Increment
Key or
the
Decrement
Key to display
C071 parameter.
c071
Press the
Enter
Key.
05
Press the
Enter
Key.
c071
5
Use the procedure on the right
to set the parameters as follows:
C072 (Communication Station
No. Selection): 1.
Slave address: 1.
Setting range 1. to 247.
c071
Press the
Increment
Key.
c072
Press the
Enter
Key.
1.
Press the
Enter
Key.
c072
C071 parameter is displayed.
Check that the displayed value is the
default value ''05''.
*If the setting is different, change the
set value.
C071parameter is displayed again.
C072 parameter is displayed.
Check that the displayed value is the
default value ''1.''.
*If the setting is different, change the
set value.
C072 parameter is displayed again.