Chapter 4: MotionBlox-40R
Table 4-8. Default Digital I/O Signal Configuration, Single Robot System
Item
Location
Type
Signal Range
1
Optional SmartController EX, XDIO
connector
12 Inputs
1001 - 1012
8 Outputs
0001 - 0008
2
eMB-40R
,
1 XIO connector
12 Inputs
1097 - 1108
8 Outputs
0097 - 0104
3
Optional IO Blox 1
8 Inputs
1113 - 1120
8 Outputs
0105 - 0112
4
Optional IO Blox 2
8 Inputs
1121 - 1128
8 Outputs
0113 - 0120
5
Optional IO Blox 3
8 Inputs
1129 - 1136
8 Outputs
0121 - 0128
6
Optional IO Blox 4
8 Inputs
1137 - 1144
8 Outputs
0129 - 0136
4.5 Using Digital I/O on eMB-40R XIO Connector
The XIO connector on the eMB-40R interface panel offers access to digital I/O, 12 inputs and 8
outputs. These signals can be used by eV+ to perform various functions in the workcell. See
the following table for the XIO signal designations.
l
12 Inputs, signals 1097 to 1108
l
8 Outputs, signals 0097 to 0104
05624-000 Rev. K
Cobra 350 User's Guide
39