5.9 Connecting 24 VDC Power to eMB-40R
Details for 24 VDC Mating Connector
The 24 VDC mating connector and two pins are supplied with each system. They are shipped
in the cable/accessories box.
Table 5-9. 24 VDC Mating Connector Specs
Connector Details
1
2
Connector receptacle, 2-position, type:
Molex Saber, 18 A, 2-Pin
Molex P/N 44441-2002
Digi-Key P/N WM18463-ND
Item 1: Ground
Item 2: +24V
Pin Details
Molex connector crimp terminal,
female, 14-18 AWG
Molex P/N 43375-0001
Digi-Key P/N WM18493-ND
Recommended crimping tool, Molex Hand
Crimper
Molex P/N 63811-0400
Digi-Key P/N WM9907-ND
NOTE:
The 24 VDC cable is not supplied with the system, but is available in
the optional Power Cable kit. See List of Cables and Parts on page 52.
Procedure for Creating 24 VDC Cable
1. Locate the connector and pins from the preceding table.
2. Use shielded two-conductor cable with 14-16 AWG wire to create the 24 VDC cable.
Select the wire length to safely reach from the user-supplied 24 VDC power supply to
the eMB-40R base.
NOTE:
You also must create a separate 24 VDC cable for the SmartController
EX. That cable uses a different style of connector. See the
SmartController
EX User's Guide
.
3. Crimp the pins onto the wires using the tool recommended in the preceding table.
4. Insert the pins into the connector. Confirm that the +24 V and Ground wires are in the
correct terminals in the plug.
5. Install a user-supplied ring lug (for an M3 screw) on the shield at the eMB-40R end of
the cable.