Chapter 5: System Cable Installation
Table 5-13. AC Power Installation with Three-Phase Supply Description
Item
Description
1
Three-phase 200-240 VAC
L = Line
N = Neutral
E = Earth Ground
2
F4 and F5 are user-supplied, must be slow-blow.
3
User-supplied AC power cable
4
eMB-40R single-phase 200-240 VAC
5
200-240 VAC
Details for AC Mating Connector
The AC mating connector is supplied with each system. It is shipped in the cable/accessories
box. The supplied plug is internally labeled for the AC power connections (L, E, N).
Table 5-14. AC Mating Connector Details
AC Connector details
AC in-line power plug,
straight, female, screw ter-
minal, 10 A, 250 VAC
Qualtek P/N 709-00/00
Digi-Key P/N Q217-ND
NOTE:
The AC power cable is not supplied with the system, but is available in
the optional Power Cable kit. See List of Cables and Parts on page 52.
Procedure for Creating 200-240 VAC Cable
1. Locate the AC mating connector shown in the preceding table.
2. Open the connector by unscrewing the screw on the shell and removing the cover.
3. Loosen the two screws on the cable clamp. See the following figure for details.
4. Use 18 AWG wire to create the AC power cable. Select the wire length to safely reach
from the user-supplied AC power source to the eMB-40R base.
5. Strip 18 to 24 mm of insulation from each of the three wires.
6. Insert the wires into the connector through the removable bushing.
05624-000 Rev. K