74
Cobra 350 User's Guide
05624-000 Rev. K
5.10 Connecting 200-240 VAC Power
7. Connect each wire to the correct terminal screw, and tighten the screw firmly.
8. Tighten the screws on the cable clamp.
9. Replace the cover and tighten the screw to seal the connector.
10. Prepare the opposite end of the cable for connection to the facility AC power source.
1
2
5
4
3
Figure 5-13. AC Power Mating Connector
Table 5-15. AC Power Mating Connector Description
Item
Description
1
Earth
2
Neutral
3
Removable bushing
4
Cable clamp
5
Line
Installing AC Power Cable to eMB-40R
1. Connect the unterminated end of the AC power cable to your facility AC power source.
See Figure 5-11. and Figure 5-12. for details. Do not turn on AC power at this time.
2. Plug the AC connector into the AC power connector on the interface panel on the eMB-
40R.
3. Secure the AC connector with the locking latch.