7-6
Section
Pulse Outputs
101
Pulse Output Specifications
All Pulse Outputs Except for One-shot Pulse Outputs
Item
Specification
Number of pulse
outputs
2 outputs (Port 1 = pulse output 1, port 2 = pulse output 2)
Signals
Pulse output CW and CCW
Max. output
frequency
200 kHz (but actual output frequencies are governed by clock frequency setting)
External power
supply
24 VDC +10%/–15%, 30 mA max.
Max. switching
capacity
NPN open-collector, 30 mA at 5 to 24 VDC
±
10%
(With 1.6 k
Ω
trimmer resistor: 16 mA at 5 to 24 VDC
±
10%)
Min. switching
capacity
NPN open-collector, 7 mA at 5 to 24 VDC
±
10%
Leakage current
0.1 mA max.
Residual voltage
0.4 V max.
Pulse output
specifications
Minimum pulse width
Pulse fre-
Switching current/load power supply
quency
7 mA/5 VDC
±
5%
30 mA/5 VDC
±
5%
7 mA/24 VDC
±
10%
30 mA/24 VDC
±
10%
t
ON
t
OFF
t
ON
t
OFF
t
ON
t
OFF
t
ON
t
OFF
50 kpps
max.
9.7
µ
s
min.
9.7
µ
s
min.
9.8
µ
s
min.
9.8
µ
s
min.
9.6
µ
s
min.
9.6
µ
s
min.
9.8
µ
s
min.
9.8
µ
s
min.
100 kpps
max.
4.7
µ
s
min.
4.7
µ
s
min.
4.8
µ
s
min.
4.8
µ
s
min.
4.6
µ
s
min.
4.6
µ
s
min.
4.8
µ
s
min.
4.8
µ
s
min.
200 kpps
max.
2.2
µ
s
min.
2.2
µ
s
min.
2.3
µ
s
min.
2.3
µ
s
min.
2.1
µ
s
min.
2.1
µ
s
min.
2.3
µ
s
min.
2.3
µ
s
min.
Note
1. The above loads are assumed to be simple resistive loads and the impedance of the
cable connecting the load is not considered.
2. The actual pulse widths may be smaller than those specified above due to pulse form
distortion caused by connection cable impedance.
Summary of Contents for CS1 -
Page 1: ...Cat No W378 E1 1 Customizable Counter Units SYSMAC CS1 CS1W HI001 HCP22 HCA22 OPERATION MANUAL...
Page 2: ......
Page 3: ...CS1W HIO01 HCP22 HCA22 Customizable Counter Units Operation Manual Produced January 2001...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ......
Page 20: ......
Page 40: ......
Page 60: ......
Page 146: ......
Page 166: ......