69
Words Allocated in DM Area
Section 4-3
m+1
00 to 07
Input and out-
put of general-
purpose data
from/to the
Customizable
Counter Unit
First word address of the output words in
the words allocated in DM Area (for output
from the CPU Unit to the Customizable
Counter Unit)
00 (BCD): Disabled (i.e., no transfer
from the CPU Unit to the Customizable
Counter Unit)
01 to 09 (BCD): Invalid (read as incor-
rect setting)
10 to 99 (BCD): Offset address for first
word (i.e., first word address = m + this
setting)
08 to 15
First word address of the input words in the
words allocated in DM Area (for input from
the CPU Unit to the Customizable Counter
Unit)
00 (BCD): Disabled (i.e., no transfer
from the Customizable Counter Unit to
the CPU Unit)
01 to 09 (BCD): Invalid (read as incor-
rect setting)
10 to 99 (BCD): Offset address for first
word (i.e., first word address = m + this
setting)
m+2
00 to 11
Output refresh (for out-
put from the CPU Unit
to the Customizable
Counter Unit)
Number of words
transferred from
the CPU Unit to
the Customizable
Counter Unit
0001 to 090 (BCD): 1 to 90 words
Note:
There are various restrictions on
the transfer of data. For example, the
total number words transferred at input
and output refresh must not exceed 90
words. (See note.)
12 to 15
Area in the Cus-
tomizable Counter
Unit
0 Hex: DM
1 Hex: IR
2 Hex: LR
3 Hex: AR
4 Hex: EM
m+3
00 to 15
First word address
in the Customiz-
able Counter Unit
0000 to the highest address in the area
specified above (BCD)
m+4
00 to 11
Input refresh (for input
from the Customiz-
able Counter Unit to
the CPU Unit)
Number of words
transferred from
the Customizable
Counter Unit to
the CPU Unit
0001 to 0090 (BCD): 1 to 90 words
Note:
There are various restrictions on
the transfer of data. For example, the
total number words transferred at input
and output refresh must not exceed 90
words. (See note.)
12 to 15
Area in the Cus-
tomizable Counter
Unit
0 Hex: DM
1 Hex: IR
2 Hex: LR
3 Hex: AR
4 Hex: EM
m+5
00 to 15
First word address
in the Customiz-
able Counter Unit
0000 to the highest address in the area
specified above (BCD)
m+6
00 to 03
Communications settings for peripheral port
0 Hex: Communications settings are
determined by the settings in DM 6651
of the Unit Setup Area.
1 Hex: Standard settings (baud rate:
9,600 bps; data length: 7 bits; 1 start
bit; 2 stop bits; even parity). The Unit
Setup (DM 6650 and DM 6651) is
invalid.
04 to 15
(Reserved by system.)
---
m+7
00 to 15
(Reserved by system.)
---
m+8
00 to 15
(Reserved by system.)
---
m+9
00 to 15
(Reserved by system.)
---
Word Bits
Function
Contents
Summary of Contents for CS1W-HCA12-V1
Page 2: ......
Page 6: ...vi...
Page 20: ...xx Conformance to EC Directives 7...
Page 38: ...18 Models and System Configurations Section 1 2...
Page 78: ...58 Fail safe Circuits Section 3 5...
Page 138: ...118 AR Area Section 6 4...
Page 204: ...184 Improved Instructions Section 7 14...
Page 222: ...202 Cycle Time Section 8 3...
Page 240: ...220 Troubleshooting Flowcharts Section 9 5...
Page 244: ...224 Precautions when Using the CX Programmer Appendix A...
Page 252: ......
Page 253: ......