86
Test Run
Section 9-1
(2) The operation on the personal computer may not stop the motor. Provide
an emergency stop device externally to enable stopping the motor imme-
diately at any time.
(3) Before starting MECHATROLINK communications, make sure that the
PLC is in the PROGRAM mode. If the PLC is in RUN or MONITOR mode,
the axis may start moving suddenly due to execution of the ladder pro-
gram. Before disconnecting MECHATROLINK communications, make
sure that the axis is not operating. Disconnecting MECHATROLINK com-
munications will put the operating axis in the Servo-free state.
(4) If a communications error occurs while the Test Run Window is being dis-
played, a FINS Command Time Monitor Error will occur in the Position
Control Unit. To clear the error, the power for the Position Control Unit
must be turned OFF and then turned ON again, the Position Control Unit
must be restarted, or the
Unit Error Reset
Button must be pressed to
clear the error and close the Test Run Window.
Test Run Window
Item
Explanation
Selected Axis
Selects the axis to jog. The axes that are registered in the Position Control
Unit are displayed.
Status
Comm
Shows the MECHATROLINK communications status.
Busy
Shows the status of the Busy Flag of the selected axis.
Present Value
Shows the feedback present value of the selected axis.
Establish/Release Con-
nection
Release Button
Releases MECHATROLINK communications when clicked.
Establish Button Establishes MECHATROLINK communications when clicked.
Servo Lock/Unlock
Servo Unlock
Button
Executes Servo Unlock when clicked.
Servo Lock But-
ton
Executes Servo Lock when clicked.
JOG Set-
tings
Speed Designation
Specifies the speed at the start of jogging.
Setting range: 0 to 2,147,483,647 [command units/s]
Override
Enable check
box
Not selected: Disables override.
Selected: Enables override.
Override value
Sets the override value.
Setting range: 1 to 327 [%]
Write Button
Writes the settings in
Speed Designation
and
Override
to the Position Con-
trol Unit. Make sure to write the settings before executing jogging.
Summary of Contents for CX-MOTION-NCF - V1.8
Page 2: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 8 Operation Manual Revised October 2008...
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Application Precautions 5...
Page 33: ...12 Connecting to PLC Section 2 2...
Page 36: ...15 Screen Name Section 3 1 Edit Parameter Windows...
Page 37: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Page 63: ...42 Editing Servo Parameters Section 5 2...
Page 68: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Page 89: ...68 Writing to Flash Memory Section 7 6...
Page 103: ...82 Axis Monitor Section 8 2...
Page 109: ...88 Test Run Section 9 1...
Page 133: ...112 Index...
Page 137: ...116 Revision History...