39
Editing Servo Parameters
Section 5-2
function may occur. (The Using Absolute Encoder parameters are as fol-
lows: W Series (with and without built-in communications): Pn002.2, G
Series (with built-in communications): Pn00B.)
(3) When setting Reversal Mode 3 for the Origin Search Operation,
Not Use
Origin Proximity
cannot be set for the Origin Detection Method.
(4) When using an Absolute Encoder and the
Preset When Origin Search
setting, only Reversal Mode 1 can be set for the Origin Search Operation.
Quitting Editing
Click the
OK
Button. Once all the editing is completed, click the
OK
Button to
finalize the edited data.
To cancel the edited data, click the
Cancel
Button.
5-2
Editing Servo Parameters
In the Axis Map Setting Window, select
Edit - Edit Parameters - Axis
@@
,
double-click an axis to be edited, or right-click an axis to be edited and select
Edit Servo Parameters
from the pop-up menu. (
@@
: 01 to 16) The Edit
Servo Parameter Window will be displayed.
Editing Servo Parameters
1,2,3...
1.
Select a parameter to be edited.
Edit a parameter either by entering a value or by selecting a value from the
drop-down list for each bit of the parameter.
For parameters whose bits are to be set, click the
Plus
Icon on the left to
display the parameters for each bit.
Item
Explanation
Download
Downloads Servo Parameters to a Servo Drive
Upload
Uploads Servo Parameters from a Servo Drive.
Compare
Compares the Servo Parameters on the computer with the ones in
the Servo Drive.
Initialize
Initializes the Servo Parameters to their default settings.
OK
Saves the parameters that are set in the Edit Servo Parameter
Window.
Cancel
Cancels the parameters that are set in the Edit Servo Parameter
Window.
Summary of Contents for CX-MOTION-NCF - V1.8
Page 2: ...CXONE AL C V3 CXONE AL D V3 CX Motion NCF Ver 1 8 Operation Manual Revised October 2008...
Page 3: ...iv...
Page 5: ...vi...
Page 21: ...xxii Application Precautions 5...
Page 33: ...12 Connecting to PLC Section 2 2...
Page 36: ...15 Screen Name Section 3 1 Edit Parameter Windows...
Page 37: ...16 Screen Name Section 3 1 Monitor Windows Axis Monitor Window Unit Monitor Window...
Page 63: ...42 Editing Servo Parameters Section 5 2...
Page 68: ...47 Print Section 6 5 Print Samples An example of printed Unit Parameters is shown below...
Page 89: ...68 Writing to Flash Memory Section 7 6...
Page 103: ...82 Axis Monitor Section 8 2...
Page 109: ...88 Test Run Section 9 1...
Page 133: ...112 Index...
Page 137: ...116 Revision History...