D41G
22
8.
If an emergency exit is available, cut square tube H at length.
De-burr the cut sides.
To be observed:
• Maximum door leaf thickness S: 170 mm
• Length of sawn off square rod H
Mounting outside
P1: L = S + 22-2 mm
• Through-hole for square tube H: Ø16 mm
9.
Unscrew the cover of the emergency exit E1
10.
Insert sliding blocks as shown (included in delivery with D41G-A2)
To be observed:
Observe the alignment (notch) of the sliding blocks
• D: for left door
• E: for right door
11.
Fit the bottom plate of the emergency exit E1 to the door
To be observed:
• Actuator completely in J (actuator unit or emergency exit unit)
retracted
• Arrange both the emergency exit and the actuator unit parallel
• Screws M6
• Tightening torque: 8 N·m
• Wall thickness of the device: 8 mm
• Washers 6.4-dia (included in delivery with D41G-A2)
• For applications with strong vibrations, please ensure the screws
are correctly secured.
12.
Insert square rod H in the backside of the actuator
To be observed:
For mounting outside: Insert chamfer of square into emergency exit
or insert cut side of square into actuator unit. Position of the chamfer
as shown, when actuator unit is actuated.
13.
Fit the cover and the handle onto the emergency exit
To be observed:
• Position of the driving shaft I as shown, when actuator unit is
actuated.
• Functional test of the emergency exit handle: it should be possible
to open the guard door inside the hazardous area; it should not be
possible to lock the guard door from inside. The emergency exit
handle must be in upright position when closed.
14.
Clip the dust-proof flap in the unused side.
To be observed:
• M: for left door
• N: for right door
15.
After being set up, secure the cover A of the manual release with
the seal, which is included in delivery with safety door switch
D41G.
Seal the cover of the manual release A
Mounting outside
H
D
E
Mounting outside
8
8
K
J
Mounting outside
H
For left door
I
For right door
I
GN
RD
YE
M
N
GN
RD
YE
A