D41G
23
D41G-A1
The actuator D41G-A1 is mounted with a return spring. The spring travel is maximum 5 mm. The distance between the flange of the actuator and
the switch enclosure must be 5 ± 1.5 mm with the actuator inserted.
1.
Unscrew cover C for the wiring compartment and open the manual
release flap A.
To be observed
Actuation of manual release with triangular key
(included in delivery with safety door switch D41G)
2.
Mount enclosure of safety door switch D41G flush with doorpost.
To be observed
• Screws M6 (not included in delivery with safety door switch D41G)
• Washers 6.4-dia (included in delivery with safety door switch
D41G)
• Tightening torque for safety door switch: 8 N•m (A)
• Tightening torque for cover screw: 0.7 to 1 N•m (Torx T10) (B)
• Wall thickness of safety door switch: 19 mm
• For applications with strong vibrations, please observe a proper
securing of the screws
3.
Fit the actuator to the doorpost.
To be observed
• Actuator with emergency exit (emergency release tab) D41G-A1-
E0 may only be installed concealed.
• Top side of the safety door switch D41G flush with actuator top side
• Distance between safety door switch D41G and actuator: 5 ± 1.5
mm
• Screws M6 (not included in delivery with safety door switch D41G)
• Washers 6.4-dia (included in delivery with actuator D41G-A1)
• Wall thickness of actuator: 8 mm
• Tightening torque 8 N·m (C)
• For applications with strong vibrations, please observe a proper
securing of the screws
4.
Clip the dust-proof cover in the unused side.
(included in delivery with safety door switch D41)
To be observed
M: for left door
N: for right door
5.
Seal the cover.
To be observed
After being put into operation, the manual release must be secured by
installing the seal, which is included in with safety door switch D41G.